首页> 美国政府科技报告 >Development of the Electrochemical Biosensor for Organophosphate Chemicals Using CNT/Ionic Liquid Bucky Gel Electrode
【24h】

Development of the Electrochemical Biosensor for Organophosphate Chemicals Using CNT/Ionic Liquid Bucky Gel Electrode

机译:用CNT /离子液体Bucky凝胶电极开发有机磷化合物电化学生物传感器

获取原文

摘要

Organophosphorus hydrolase (OPH) immobilized on CNT/ionic liquid (IL) electrodes were prepared by using three different intrinsic kinds of ILs, as binders. CNTs/ILs lead to dramatic electrochemical enhancements with respect to response time, stability, and sensitivity of composite electrodes. In addition, the electrochemical and biocatalytic properties of three-composite electrodes were strongly influenced by different types of ILs used, as verified by cyclic voltammetry and chronoamperometry. These results were attributed to the conformational changes of the microenvironment between the OPH and the composite electrodes within three different types of ILs. In particular, the biocatalytic signals of three OPH/CNT/ILs modified electrodes increased linearly to the concentration of paraoxon in a wide range of 2'20 lM. These findings provide a deep understanding of the role of each IL on the modified electrodes, enabling to enhance electrochemical properties for biosensors.