首页> 美国政府科技报告 >Head and Neck Cooling by Air, Water, or Air Plus Water in Hyperthemia.
【24h】

Head and Neck Cooling by Air, Water, or Air Plus Water in Hyperthemia.

机译:高血压患者通过空气,水或空气加水对头部和颈部进行冷却。

获取原文

摘要

The effects of air, water, and air plus water head cooling on thermoregulatory responses and human operator performance were studied in nonacclimatized, heat-exposed men. Forty chamber exposures (46 C, 30 mm Hg water vapor pressure) were conducted under noncooled and the aforementioned subconditions of head cooling. Five subjects, exposed for 80 min, were monitored for mean skin and rectal temperatures, heart rate, sweat loss, and compensatory tracking performance. A modified Air Force helmet shell provided facial air ventilation (24 C) at 8 cfm. Eight interconnected neoprene modules fastened beneath a helmet liner provided water cooling (20 C at 0.9 1/min). Tracking performance was unchanged across conditions. Elevation of rectal temperature and heart rate, sweat loss, and Physiological Index of Strain were significantly reduced by each condition of head cooling. Air is as effective as water as a cooling agent. Air ventilation acts synergistically with water cooling in reducing physiological strain. Relative merits of each approach to head cooling, in an operational context, are discussed. (Author)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号