首页> 美国政府科技报告 >Effectiveness of a Dot-Blot Immunoassay off Anti-Rickettsia TsutsugamushiAntiibodies for Serologic Analysis of Scrub Typhus
【24h】

Effectiveness of a Dot-Blot Immunoassay off Anti-Rickettsia TsutsugamushiAntiibodies for Serologic Analysis of Scrub Typhus

机译:针对抗立克次体恙虫病抗体的斑点免疫分析对丛林斑疹伤寒血清学分析的有效性

获取原文

摘要

We compared a commercially available dot-blot immunoassay system with theindirect immunofluorescence assay (IFA) in tests of known negative and known positive sera from scrub typhus cases. Using a panel of 100 sera from patients with various rickettsial and non-rickettsial infections, we observed that the IFA was 99% specific and the dipstick assay was 98% specific. In tests of 91 sera (30 negative and 61 positive for scrub typhus antibodies) from a study of febrile patients in Malaysia, using the standard of an IFA titer % 1:64 as negative, an IFA titer > 1:128 as positive, and an IFA titer 1:64 as either positive or negative (supported by clinical records), dipsticks were 83% specific and 90% sensitive. The quantitative correlation of the dipsticks to IFA titers was confirmed by significant differences in geometric means of inverse IFA titers corresponding to the number of positive dipstick spots (no dots 8.5, one dot 43.3, two dots 206.7, and three dots 676.9). The assay would enable physicians and public health workers who deal with patients to quickly diagnose and appropriately treat most cases of the disease, especially in areas of high prevalence where the proportion of false-positive results to true-positive results would be low.