There has been a high rate of false alarms for the critical electrocardiogram (ECG) arrhythmia events in intensive care units (ICUs), from which the 'crying-wolf' syndrome may be resulted and patient safety may be jeopardized. This article presents an algorithm to reduce false critical arrhythmia alarms using arterial blood pressure (ABP) and/or photoplethysmogram (PPG) waveform features. We established long duration reference alarm datasets which consist of 573 ICU waveform-alarm records (283 for development set and 290 for test set) with total length of 551 patent days. Each record has continuous recordings of ECGs, ABP and/or PPG signals and contains one or multiple critical ECG alarms. The average length of a record is 23 h. There are totally 2408 critical ECG alarms (1414 in the development set and 994 in the test set), each of which was manually annotated by experts. The algorithm extracts ABP/PPG pulse features on a beat-by-beat basis. For each pulse, five event feature indicators (EFIs), which correspond to the five critical ECG alarms, are generated. At the time of a critical ECG alarm, the corresponding EFI values of those ABP/PPG pulses around the alarm time are checked for adjudicating (accept/reject) this alarm. The algorithm retains all (100%) the true alarms and significantly reduces the false alarms. Our results suggest that the algorithm is effective and practical on account of its real-time dynamic processing mechanism and computational efficiency.
机译:重症监护病房(ICU)的严重心电图(ECG)心律失常事件的误报率很高,可能导致“哭狼”综合征,并危及患者的安全。本文提出了一种使用动脉血压(ABP)和/或光体积描记图(PPG)波形特征来减少错误的严重心律失常警报的算法。我们建立了长期参考警报数据集,该数据集由573个ICU波形警报记录(开发集283个,测试集290个)组成,总长度为551个专利日。每条记录具有ECG,ABP和/或PPG信号的连续记录,并且包含一个或多个紧急ECG警报。记录的平均长度为23小时。总共有2408个紧急ECG警报(开发集中为1414,测试集中为994),每个警报都由专家手动注释。该算法逐个节拍地提取ABP / PPG脉冲特征。对于每个脉冲,将生成与五个紧急ECG警报相对应的五个事件特征指示器(EFI)。在紧急ECG警报时,将检查警报时间前后那些ABP / PPG脉冲的相应EFI值,以裁定(接受/拒绝)此警报。该算法保留所有(100%)真实警报,并显着减少了虚假警报。我们的结果表明,由于其实时动态处理机制和计算效率,该算法是有效且实用的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号