Mega composite structure systems have been widely used in high rise buildings in China. Compared to other structures, this type of composite structure systems has a larger cross-section with less weight. Concrete filled steel tubular (CFST) laced column to box-beam connections are gaining popularity, in particular for the mega composite structure system in high rise buildings. To enable a better understanding of the destruction characteristics and aseismic performance of these connections, three different connection types of specimens including single-limb bracing, cross bracing and diaphragms for core area of connections were tested under low cyclic and reciprocating loading. Hysteresis curves and skeleton curves were obtained from cyclic loading tests under axial loading. Based on these tested curves, a new trilinear hysteretic restoring force model considering rigidity degradation is proposed for CFST laced column to box-beam connections in a mega composite structure system, including a trilinear skeleton model based on calculation, law of stiffness degradation and hysteresis rules. The trilinear hysteretic restoring force model is compared with the experimental results. The experimental data shows that the new hysteretic restoring force model tallies with the test curves well and can be referenced for elastic-plastic seismic analysis of CFST laced column to composite box-beam connection in a mega composite structure system.
机译:巨型复合结构系统已在中国的高层建筑中广泛使用。与其他结构相比,这种类型的复合结构系统具有更大的横截面和更轻的重量。钢管混凝土(CFST)系柱到箱形梁的连接正日益普及,特别是对于高层建筑中的大型复合结构系统。为了更好地理解这些连接的破坏特性和抗震性能,在低循环和往复载荷下测试了三种不同的连接类型的样本,包括单肢支撑,交叉支撑和用于连接核心区域的隔板。磁滞曲线和骨架曲线是通过轴向载荷下的循环载荷试验获得的。基于这些测试曲线,为巨型复合结构系统中的CFST系柱到箱梁的连接提出了一种考虑刚度退化的三线性滞后恢复力模型,包括基于计算,刚度退化定律和滞后规则的三线性骨架模型。 。将三线性滞后恢复力模型与实验结果进行了比较。实验数据表明,新的滞后恢复力模型与试验曲线吻合良好,可为大型组合结构系统中CFST系柱至组合箱梁连接的弹塑性地震分析提供参考。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号