...
首页> 外文期刊>Spectrochimica Acta, Part B. Atomic Spectroscopy >Direct determination of trace rare earth elements in ancient porcelain samples with slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry
【24h】

Direct determination of trace rare earth elements in ancient porcelain samples with slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry

机译:浆料采样电热蒸发电感耦合等离子体质谱法直接测定古瓷样品中的微量稀土元素。

获取原文
获取原文并翻译 | 示例
           

摘要

A method for the direct determination of trace rare earth elements in ancient porcelain samples by slurry sampling fluorinating electrothermal vaporization inductively coupled plasma mass spectrometry was developed with the use of polytetrafluoroethylene as fluorinating reagent.It was found that Si,as a main matrix element in ancient porcelain sample,could be mostly removed at the ashing temperature of 1200 deg C without considerable losses of the analytes.However,the chemical composition of ancient porcelain sample is very complicated,which makes the influences resulting from other matrix elements not be ignored.Therefore,the matrix effect of ancient porcelain sample was also investigated,and it was found that the matrix effect is obvious when the matrix concentration was larger than 0.8 g 1~(-1).The study results of particle size effect indicated that when the sample particle size was less than 0.057 mm,the particle size effect is negligible.Under the optimized operation conditions,the detection limits for rare earth elements by fluorinating electrothermal vaporization inductively coupled plasma mass spectrometry were 0.7 ng g~(-1) (Eu)-33.3 ng g~(-1)(Nd) with the precisions of 4.1% (Yb)-10%(La) (c=l ng l~(-1),n = 9).The proposed method was used to directly determine the trace rare earth elements in ancient porcelain samples produced in different dynasty (Sui,Ming and Qing),and the analytical results are satisfactory.? 2005 Elsevier B.V.All rights reserved.
机译:以聚四氟乙烯为氟化试剂,开发了一种通过浆液进样-氟化电热汽化-电感耦合等离子体质谱法直接测定古瓷器样品中微量稀土元素的方法。瓷器样品可以在1200℃的灰化温度下除去,而不会造成分析物的大量损失。但是,古代瓷器样品的化学成分非常复杂,因此不能忽略其他基质元素的影响。因此,对古瓷样品的基质效应进行了研究,发现当基质浓度大于0.8 g 1〜(-1)时,基质效应明显。粒径小于0.057 mm,粒径影响可忽略不计。在优化的操作条件下,t氟化电热汽化电感耦合等离子体质谱法检测稀土元素的检出限为0.7 ng g〜(-1)(Eu)-33.3 ng g〜(-1)(Nd),精度为4.1%(Yb)- 10%(La)(c = l ng l〜(-1),n = 9)。该方法用于直接测定不同时期(隋,明,清)生产的古代瓷器样品中的痕量稀土元素。 ,分析结果令人满意。 2005 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号