首页> 外文期刊>Solid state ionics >Hydrogen isotope cell and its application to hydrogen isotope sensing
【24h】

Hydrogen isotope cell and its application to hydrogen isotope sensing

机译:氢同位素池及其在氢同位素传感中的应用

获取原文
获取原文并翻译 | 示例
           

摘要

The EMFs of hydrogen isotope cells with H-2-D-2 gas mixtures against H-2 and D-2 reference gases were measured at 700 degreesC using CaZr0.90In0.10O3-alpha as a proton-conducting solid electrolyte. Steady electromotive forces (EMFs) with quick response were obtained. The EMFs were almost linear functions of the gas composition of the H-2-D-2 mixtures and were consistent with those theoretically estimated. Such defined EMFs can he used to monitor H-2/D-2 ratio in hydrogen isotope mixtures. (C) 2000 Elsevier Science B.V. All rights reserved. [References: 10]
机译:使用CaZr0.90​​In0.10O3-alpha作为质子传导性固体电解质,在700摄氏度下测量含H-2-D-2气体混合物与H-2和D-2参考气体的氢同位素电池的EMF。获得具有快速响应的稳定电动势(EMF)。 EMF几乎是H-2-D-2混合物中气体成分的线性函数,与理论估计值一致。这样定义的EMF可以用来监视氢同位素混合物中的H-2 / D-2比。 (C)2000 Elsevier Science B.V.保留所有权利。 [参考:10]