...
首页> 外文期刊>Otology and neurotology: official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology >Impedance, neural response telemetry, and speech perception outcomes after reimplantation of cochlear implants in children
【24h】

Impedance, neural response telemetry, and speech perception outcomes after reimplantation of cochlear implants in children

机译:儿童人工耳蜗植入后的阻抗,神经反应遥测和语音感知结果

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: To compare mean impedance levels, neural response telemetry (NRT), and auditory perception after initial and explant-reimplant pediatric cochlear implants. STUDY DESIGN: Retrospective case review. SETTING: Tertiary referral hospital and cochlear implant program. PATIENTS: Children 0 to 16 years inclusive who have undergone explant-reimplant of their cochlear implant. INTERVENTION: Impedance levels, NRT, and speech perception performance. MAIN OUTCOME MEASURES: Impedance, NRT, and auditory perception at switch on, 3 months, 12 months, 3 years, and 5 years after initial cochlear implant and reimplantation. RESULTS: The explant-reimplant group receiving Cochlear contour array had significantly (p < 0.001) raised impedance at switch on, 3 months, 12 months, and 3 years, compared with their initial implant. The explant-reimplant group receiving Cochlear straight array had marginally significant (p = 0.045) raised impedance at switch on, 3 months, 12 months, and 3 and 5 years. Infection was associated with greater increases in impedance in the reimplant Contour group. NRT was increased in the explant-reimplant group but not significantly (p = 0.06). Auditory perception returned to preexplant levels within 6 months in 61% of children. CONCLUSION: Impedance is higher after explant-reimplant and remains increased for years after explant-reimplant with Cochlear contour and to a lesser degree the straight array device.
机译:目的:比较初次和外植-小儿人工耳蜗植入后的平均阻抗水平,神经反应遥测(NRT)和听觉。研究设计:回顾性病例回顾。地点:三级转诊医院和人工耳蜗计划。患者:0至16岁(含0和16岁)的儿童,他们接受了人工耳蜗的外植-再植。干预:阻抗水平,NRT和语音感知性能。主要观察指标:初次人工耳蜗植入和再植入后3个月,12个月,3年和5年开机时的阻抗,NRT和听觉感知。结果:与最初的植入物相比,接受耳蜗轮廓阵列的植入物-植入物组在开启,3个月,12个月和3年时阻抗显着提高(p <0.001)。接受Cochlear笔直阵列的外植体-再植体组在开启,3个月,12个月以及3和5年时阻抗略有升高(p = 0.045)。再感染等高线组感染与阻抗的更大增加有关。在外植体-再植体组中,NRT升高,但没有显着升高(p = 0.06)。 61%的儿童在6个月内听觉恢复到了种植前的水平。结论:植体再植入后阻抗较高,并且在植有耳蜗轮廓的植体再植入后的几年中仍会增加,而在较小程度上是笔直阵列装置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号