Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound.

机译:使用Pentacam,Orbscan和超声波进行中央角膜厚度测量的可重复性和可重复性。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: The purpose of this study was to compare central corneal thickness (CCT) measurements obtained with a novel rotating Scheimpflug camera (Pentacam; Oculus) with scanning slit topography (Orbscan; Bausch & Lomb), and with ultrasound pachymetry (SP-2000; Tomey). METHODS: CCT in 30 healthy eyes was measured twice with each modality by 2 independent observers in random order. The results from scanning slit topography are given both with and without multiplication with the "acoustic correction factor" of 0.92. In addition, the displayed images from the rotating Scheimpflug camera and scanning slit topography were used to calculate the signal difference-to-noise ratios (SD/N) between cornea and background signal. RESULTS: The mean CCT values as determined with the different modalities (+/-standard deviation) were: 542+/-29 microm, 576+/-37 microm, 530+/-34 microm, and 552+/-32 microm for rotating Scheimpflug imaging, for uncorrected and for corrected scanning slit pachymetry, and for ultrasound, respectively. The differences between modalities (+/-95% limits of agreement) were -9.8+/-31 microm between rotating Scheimpflug and ultrasound, 24+/-31.2 microm between scanning slit and ultrasound, and 33+/-27 microm between scanning slit and rotating Scheimpflug imaging. The limits of agreement for within and between observer effects were within 4.2% of the absolute CCT values for scanning slit and ultrasound and within 2.2% for the rotating Scheimpflug imaging. The rotating Scheimpflug camera showed similar SD/N ratios but steeper edges of the corneal surfaces in the intensity profile plots. CONCLUSION: In the assessment of normal corneas, the Pentacam measured CCT values closer to ultrasound pachymetry and with less variability compared with Orbscan. The (interobserver) reproducibility with the Pentacam was highest of all 3 modalities.
机译:目的:本研究的目的是比较使用新型旋转Scheimpflug相机(Pentacam; Oculus),扫描狭缝形貌(Orbscan; Bausch&Lomb)和超声测厚法(SP-2000; S-2000)获得的角膜中央厚度(CCT)测量值。 Tomey)。方法:由2位独立观察员以随机顺序对30种健康眼睛的CCT进行两次测量,每种方式均如此。扫描狭缝形貌的结果在有和没有乘以0.92的“声学校正系数”的情况下给出。此外,旋转的Scheimpflug相机和扫描狭缝形貌显示的图像用于计算角膜和背景信号之间的信号差噪比(SD / N)。结果:用不同的模态(+/-标准偏差)确定的平均CCT值是:542 +/- 29微米,576 +/- 37微米,530 +/- 34微米和552 +/- 32微米旋转Scheimpflug成像,分别用于未校正和校正后的扫描狭缝测厚法以及超声检查。模态之间的差异(一致性的+/- 95%限制)是旋转Scheimpflug和超声之间的差异为-9.8 +/- 31微米,扫描狭缝和超声之间的差异为24 +/- 31.2微米,扫描狭缝之间的差异为33 +/- 27微米和旋转Scheimpflug成像。对于观察狭缝和超声,观察者效应之内和之间的一致性限制在绝对CCT值的4.2%以内,而旋转Scheimpflug成像则在2.2%以内。旋转的Scheimpflug相机在强度分布图中显示出相似的SD / N比,但角膜表面的边缘较陡。结论:在评估正常角膜中,与Orbscan相比,Pentacam测量的CCT值更接近超声测厚法,并且变异性较小。在所有三种方式中,Pentacam的(观察者间)再现性最高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号