首页> 外文期刊>Radiation Physics and Chemistry >How do monomeric components of a polymer gel dosimeter respond to ionising radiation: A steady-state radiolysis towards preparation of a 3D polymer gel dosimeter
【24h】

How do monomeric components of a polymer gel dosimeter respond to ionising radiation: A steady-state radiolysis towards preparation of a 3D polymer gel dosimeter

机译:聚合物凝胶剂量计的单体成分如何响应电离辐射:制备3D聚合物凝胶剂量计的稳态放射分解

获取原文
获取原文并翻译 | 示例
           

摘要

Ionising radiation-induced reactions of aqueous single monomer solutions and mixtures of poly (ethylene glycol) diacrylate (PEGDA) and N,N'-methylenebisacrylamide (Bis) in a steady-state condition are presented below and above gelation doses in order to highlight reactions in irradiated 3D polymer gel dosimeters, which are assigned for radiotherapy dosimetry. Both monomers are shown to undergo radical polymerisation and cross-linking, which result in the measured increase in molecular weight and radius of gyration of the formed polydisperse polymer coils. The formation of nanogels was also observed for Bis solutions at a low concentration. In the case of PEGDA-Bis mixtures, co-polymerisation is suggested as well. At a sufficiently high radiation dose, the formation of a polymer network was observed for both monomers and their mixture. For this reason a sol-gel analysis for PEGDA and Bis was performed gravimetrically and a proposition of an alternative to this method employing a nuclear magnetic resonance technique is made. The two monomers were used for preparation of 3D polymer gel dosimeters having the acronyms PABIG and PABIG~(nx). The latter is presented for the first time in this work and is a type of the formerly established PABIG polymer gel dosimeter. The elementary characteristics of the new composition are presented, underlining the ease of its preparation, low dose threshold, and slightly increased sensitivity but lower quasi-linear range of dose response in comparison to PABIG.
机译:为了突出反应,在稳定剂量下,分别给出了单单体水溶液和聚(乙二醇)二丙烯酸酯(PEGDA)与N,N'-亚甲基双丙烯酰胺(Bis)在稳态下的混合物的电离辐射诱导反应。在辐射的3D聚合物凝胶剂量计中,这些剂量计用于放射治疗剂量测定。已显示两种单体均发生自由基聚合和交联,这导致所测得的形成的多分散聚合物线圈的分子量和回转半径增加。在低浓度的Bis溶液中也观察到了纳米凝胶的形成。在PEGDA-Bis混合物的情况下,也建议进行共聚。在足够高的辐射剂量下,对于单体及其混合物均观察到聚合物网络的形成。因此,通过重量分析法对PEGDA和Bis进行了溶胶-凝胶分析,并提出了使用核磁共振技术替代该方法的建议。两种单体用于制备首字母缩写为PABIG和PABIG_(nx)的3D聚合物凝胶剂量计。后者是这项工作中的首次展示,它是以前建立的PABIG聚合物凝胶剂量计的一种。介绍了新组合物的基本特征,强调了其制备的简便性,低剂量阈值,灵敏度略有提高,但与PABIG相比剂量响应的准线性范围较低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号