Over the past few years a variety of equivalent dose (DE) determination techniques for quartz, which are truly single aliquot-based, have been proposed. Such methods avoid the need for inter-aliquot normalisation, and provide considerable improvements in the precision of equivalent dose (DE) estimates. Much of the research leading to these developments have been based on detailed investigations of a few samples, primarily from Australia. All 'protocols' developed have performed impressively. It is necessary, however, to verify the consistency of the single aliquot DE determination methods on a wide range of samples before they can be considered as prescribed or standard. We have analysed approximately 100 samples from a range of sedimentary environments and geological provinces in an attempt to confirm the robustness of the single aliquot techniques. Up to 65% of samples measured in our laboratory were not suited to analysis via application of single aliquot additive dose (SAAD) procedures. This relates to a range of factors, including lack of sample sensitivity and dose dependent sensitivity changes. Furthermore, we have observed some problems in dating young sediments using single aliquot regeneration (SAR) methods. Critically, we observe that sample to sample variability on quartz luminescence (thermally- and optically-stimulated) behaviour is considerable, and many samples are found to exhibit behaviour which contrasts greatly from that described in recent phenomenological studies. (C) 2000 Elsevier Science Ltd. All rights reserved. [References: 24]
机译:在过去的几年中,已经提出了各种石英的等效剂量(DE)测定技术,这些技术实际上是基于等分试样的。这样的方法避免了对等分试样之间的归一化的需要,并且在等效剂量(DE)估计的精度上提供了相当大的改进。导致这些发展的许多研究都基于对一些样品的详细研究,这些样品主要来自澳大利亚。所有开发的“协议”都表现出色。但是,有必要在考虑将其视为规定或标准样品之前,对多种样品进行单等分DE测定方法的一致性进行验证。我们已经分析了一系列沉积环境和地质省份中的大约100个样本,以确认单等分技术的可靠性。在我们实验室中测量的样本中,多达65%的样本不适合通过应用单等分添加剂剂量(SAAD)程序进行分析。这与一系列因素有关,包括缺乏样品敏感性和剂量依赖性敏感性变化。此外,我们还发现了使用单等分再生(SAR)方法对年轻沉积物进行测年的一些问题。至关重要的是,我们观察到样品在石英发光(热和光学刺激)行为方面的差异很大,并且发现许多样品表现出的行为与最近的现象学研究所描述的行为有很大的差异。 (C)2000 Elsevier ScienceLtd。保留所有权利。 [参考:24]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号