Introduction:The use of bioabsorbable interference screws has become popular for treatment of avulsion fractures of the posterior cruciate ligament (PCL). Complications are uncommon. We report a case of severe chondral damage caused by the early breakage of an absorbable screw head after fixation of an avulsion fracture of the tibial attachment of the PCL. The patient felt a sudden locking of the knee when getting off a car at 4 months after the PCL surgery. MRI revealed intraarticular migration of the head of the interference screw. During revision surgery, the broken part was removed without incident, and severe cartilage damage was observed. The patient experienced a complete resolution of symptoms at the 6-month follow-up.Conclusion:MRI examination is recommended in case of sudden locking of the knee for patients undergoing PCL fixation with bioabsorbable interference screws. Surgical treatment should be performed immediately when screw breakage was confirmed.
机译:简介:生物可吸收干涉螺钉的使用已广泛用于治疗后交叉韧带(PCL)的撕脱性骨折。并发症并不常见。我们报道了一例由于PCL胫骨附件撕脱性骨折固定后,可吸收螺钉头的早期断裂而导致严重的软骨损伤。 PCL手术后四个月下车时,患者感到膝盖突然卡住。 MRI显示干涉螺钉头部的关节内移动。在翻修手术中,断裂的部分没有被切除,并且观察到严重的软骨损伤。结论:在6个月的随访中,患者的症状得到了完全解决。结论:对于使用生物可吸收的干扰螺钉进行PCL固定的患者,如果膝盖突然锁定,建议进行MRI检查。确认螺丝断裂后应立即进行手术治疗。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号