In vivo evaluation of a novel, wrist-mounted arterial pressure sensing device versus the traditional hand-held tonometer

机译:与传统的手持式眼压计相比,新型,腕上安装式动脉压传感装置的体内评估

获取原文
获取原文并翻译 | 示例
           

摘要

Although hemodynamic parameters can be assessed non-invasively, state-of-the-art non-invasive systems generally require an expert operator and are not applicable for ambulatory measurements. These limitations have restricted our understanding of the continuous behavior of hemodynamic parameters. In this manuscript, we introduce a novel wrist-mounted device that incorporates an array of pressure sensors which can be used to extract arterial waveforms and relevant pulse wave analysis biomarkers. In vivo evaluation is performed with Bland-Altman analysis to compare the novel sensor to a gold-standard hand-held tonometer by assessing their reproducibility and agreement in peripheral augmentation index (AIx) estimation at the radial artery. Arterial waves from 28 randomly selected participants were recorded in a controlled environment. Initially we assess the reproducibility of AIx results for both devices. The intra-class correlation coefficient (ICC) and mean difference +/- SD were [0.913, 0.033 +/- 0.048] and [0.859, 0.039 +/- 0.076] for the hand-held and the wrist-mounted tonometer respectively. We then show that the AIx values derived from the novel tonometer have good agreement, accuracy, and precision when compared against the AIx values derived from the reference hand-held tonometer (ICC 0.927, mean difference 0.026 +/- 0.049). In conclusion, we have presented evidence that the new wrist-mounted arterial pressure sensor records arterial waveforms that can be processed to yield AIx values that are in good agreement with its traditional hand-held counterpart. (C) 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
机译:尽管可以非侵入性地评估血液动力学参数,但是最新的非侵入性系统通常需要专业的操作员,不适用于动态测量。这些局限性限制了我们对血液动力学参数连续行为的理解。在本手稿中,我们介绍了一种新颖的腕戴式设备,该设备结合了一系列压力传感器,可用于提取动脉波形和相关的脉搏波分析生物标记物。通过Bland-Altman分析进行体内评估,以通过评估their动脉的外周扩增指数(AIx)的可重复性和一致性,将新型传感器与金标准手持眼压计进行比较。在受控的环境中记录了来自28个随机选择的参与者的动脉波。最初,我们评估两种设备的AIx结果的可重复性。对于手持式和手腕式眼压计,组内相关系数(ICC)和平均差+/- SD分别为[0.913,0.033 +/- 0.048]和[0.859,0.039 +/- 0.076]。然后,我们证明,与从参考手持式眼压计得出的AIx值相比,从新型眼压计得出的AIx值具有良好的一致性,准确性和精度(ICC 0.927,平均差0.026 +/- 0.049)。总而言之,我们已经提供了证据,表明新的腕上安装式动脉压力传感器记录的动脉波形可以进行处理以产生与传统手持设备相当的AIx值。 (C)2016年IPEM。由Elsevier Ltd.出版。保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号