首页> 外文期刊>Canadian Geotechnical Journal >Influence of reaction piles on the behaviour of a test pile in static load testing
【24h】

Influence of reaction piles on the behaviour of a test pile in static load testing

机译:在静载荷测试中,反应桩对试验桩性能的影响

获取原文
获取原文并翻译 | 示例
           

摘要

This paper employs a simplified analytical method to investigate the influence of reaction piles on the load-displacement behaviour of a test pile in static load testing. A parametric study is conducted to examine the effects of factors such as pile spacing ratio, pile slenderness ratio, and pile soil stiffness ratio. Several soil profiles are considered in the study. The parametric study also includes the cases of static load testing in the lateral direction. The correction factors for the initial pile head stiffness obtained from static pile load tests with the use of reaction piles are given in charts. Furthermore, analyses of centrifuge modelling of axially loaded piles are carried out using the simplified analytical method. Good agreements between the test results and the analysis results are demonstrated, and the applicability of the correction factors is verified.
机译:本文采用简化的分析方法来研究静载荷试验中反应堆对试验桩的载荷-位移行为的影响。进行了参数研究,以检查诸如桩间距比,桩细长比和桩土刚度比等因素的影响。研究中考虑了几种土壤剖面。参数研究还包括横向静载荷测试的情况。图表中给出了使用反作用桩通过静力桩载荷试验获得的初始桩头刚度的校正系数。此外,使用简化的分析方法对轴向加载桩的离心模型进行了分析。证明了测试结果与分析结果之间的良好一致性,并验证了校正因子的适用性。