A method for total Hg determination in fish tissue using cold vapor capacitively coupled plasma microtorch optical emission spectrometry was evaluated. The low-cost miniaturized analytical system includes a low power plasma microtorch (10 W) and low Ar consumption (150 ml min(-1)) and a QE65Pro microspectrometer as detector. Lyophilized fish tissues were microwave-assisted digested in HNO3-H2O2 mixture, brought in 5 % (v/v) HCl, then Hg vapor was chemically generated with 20 % SnCl2 solution stabilized in 15 % (v/v) HCl. The figures of merit of the proposed method were evaluated by analyzing certified reference materials and test samples and compared to those of the well-established thermal decomposition atomic absorption spectrometry method. The analytical characteristics (limits of detection and quantification, precision, and accuracy) comply with requirements for Hg determination in seafood set out in Decisions 2007/333/EC and 2002/657/EC. The limits of detection and quantification of the proposed method were 3 and 9 mu g kg(-1) Hg in dry mass, similar to those in thermal decomposition atomic absorption spectrometry. The precision was between 1.8 and 5.5 % for concentrations in the range 0.18-0.76 mg kg(-1) Hg, while the accuracy was 99.7 +/- 3.0 %. The significance tests revealed no difference between the results obtained by the two methods. The proposed miniaturized spectrometric equipment could be the subject of prototyping as low-cost instrumentation for designed applications in seafood control.
机译:评价了使用冷蒸气电容耦合等离子体微炬光发射光谱法测定鱼组织中总汞的方法。低成本的小型分析系统包括一个低功率等离子体微炬(10 W)和低Ar消耗(150 ml min(-1))和一个QE65Pro显微光谱仪作为检测器。将冻干的鱼组织在HNO3-H2O2混合物中进行微波辅助消化,加入5%(v / v)HCl,然后用稳定在15%(v / v)HCl中的20%SnCl2溶液化学生成汞蒸气。通过分析认证的参考材料和测试样品评估了该方法的优值,并将其与完善的热分解原子吸收光谱法进行了比较。分析特性(检测和定量极限,精确度和准确度)符合第2007/333 / EC号和2002/657 / EC号决定中对海鲜中汞的测定要求。该方法的检测和定量限制为干重3和9μg kg(-1)Hg,类似于热分解原子吸收光谱法。对于0.18-0.76 mg kg(-1)Hg范围内的浓度,精度在1.8到5.5%之间,而精度为99.7 +/- 3.0%。显着性检验显示两种方法获得的结果之间没有差异。拟议的小型光谱仪可能是低成本产品,可作为海鲜控制中设计应用的原型。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号