首页> 外文期刊>Geostandards and geoanalytical research >U-Pb Zircon Geochronology with an Integrated LA-ICP-MS Microanalytical Workstation: Achievements in Precision and Accuracy
【24h】

U-Pb Zircon Geochronology with an Integrated LA-ICP-MS Microanalytical Workstation: Achievements in Precision and Accuracy

机译:具有集成式LA-ICP-MS微分析工作站的U-Pb锆石年代学:精度和准确性方面的成就

获取原文
获取原文并翻译 | 示例
           

摘要

Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) is a microanalytical tool especially suitable for providing fast and precise U-Pb geochronological results on zircon grains. A new 193 nm excimer laser adapted to a micromachining workstation, equipped with a newly designed two-volume ablation cell and coupled with a quadrupole ICP-MS, is presented here. The system was tuned routinely to achieve sensitivities in the range of 3000 cps/mu g g-1 for 238U (< 2% RSD), with a 34 mu m spot size, at 5 Hz and similar to 8 J cm-2, while ablating the NIST SRM 612 glass reference material. The system was capable of providing fast (< 1.5 minutes each analysis) and precise (generally < 1.5% 1s errors) 206Pb/238U zircon ages. The ages of widely used reference material zircons (Plesovice, 337 Ma; Temora, 416 Ma; R33, 418 Ma; Sri Lanka, 564 Ma; 91500, 1065 Ma) could be precisely matched, with an accuracy on isotopic ratios that ranged from similar to 2 to similar to 6%, depending on the homogeneity of the natural reference materials.La technique de spectrometrie de masse couplee a un plasma inductif et associee a un systeme d'ablation laser (LA-ICP-MS) est un outil micro analytique particulierement adapte pour acquerir rapidement et precisement des donnees geochronologiques U-Pb sur zircons. Un systeme comportant un nouveau laser "excimer 193 nm" adapte a une micro station de travail, equipee d'une cellule d'ablation a deux volumes de conception nouvelle et couplee a une ICP-MS quadripolaire est presente. Le systeme a ete mis au point pour atteindre en routine, lorsque le verre de reference NIST SRM 612 est ablate, des sensibilites de 3000 cps/mu g g-1 pour 238U (< 2% RSD), en utilisant un spot de 34 mu m de diametre a 5 Hz et similar to 8 J cm-2. Le systeme a ete capable de fournir rapidement (temps d'analyse < 1.5 minutes) des ages 206Pb/238U precis (generalement ecart type de mesure < 1.5%). Les ages de zircons de reference largement utilises dans la litterature (Plesovice, 337 Ma; Temora, 416 Ma; R33, 418 Ma; Sri Lanka, 564 Ma; 91500, 1065 Ma) ont pu etre retrouves, avec une precision sur les rapports isotopiques variant de similar to 2 a similar to 6%, en fonction de l'homogeneite des materiaux de reference naturelle.
机译:激光烧蚀-电感耦合等离子体质谱法(LA-ICP-MS)是一种微分析工具,特别适用于在锆石晶粒上提供快速而精确的U-Pb年代学结果。本文介绍了一种适用于微加工工作站的新型193 nm受激准分子激光器,该激光器配备了新设计的两体积消融池并与四极杆ICP-MS耦合。对该系统进行常规调试,以实现对238U(<2%RSD)的灵敏度在3000 cps /μg-1的范围内,光斑大小为34μm,频率为5 Hz,与8 J cm-2相似,而烧蚀NIST SRM 612玻璃参考材料。该系统能够提供快速(每次分析<1.5分钟)和精确(通常<1.5%1s错误)206Pb / 238U锆石年龄。可以精确地匹配广泛使用的参考材料锆石的年龄(Plesovice,337 Ma; Temora,416 Ma; R33,418 Ma;斯里兰卡,564 Ma; 91500,1065 Ma),其同位素比的准确度在相似范围内。到2到6%左右,这取决于天然参比材料的均质性。质谱技术结合了非等离子体感应和辅助系统消融激光(LA-ICP-MS)以及微观分析适应性,适应性,快速性和精确性。新型系统激光器“准分子193 nm”适应了微型计算机的需求,装备了新的概念性的新型设备,并结合了ICP-MS的最新技术。例行的常规注水,参考标准NIST SRM 612烧蚀,敏化度为3000 cps /μg-1倒注238U(RSD <2%),有效点为34 mu直径为5 Hz等,与8 J cm-2相似。系统可以快速进行定量分析(分析时间<1.5分钟),达到206Pb / 238U精确度(生成电子心率类型的检验<1.5%)。大型参考文献利用单方面文献(Plesovice,337 Ma; Temora,416 Ma; R33,418 Ma;斯里兰卡,564 Ma; 91500,1065 Ma)进行深度研究,并在同等精度上进行了精密的研究类似于2的变种,类似于6%的变种,参考自然物质的功能。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号