High resolution body surface potential maps and an equivalent current dipole model of the cardiac generator were used to assess the heart state in two abnormal conditions:WPW syndrome with single accessory pathway and local ventricular ischemia.Results of a simulation study and experimental verification of the method for both cardiologic abnormalities are presented.Single accessory pathway in WPW syndrome was simulated as initial ventricular activation at the atrio-ventricular ring.Using a current dipole model of the cardiac generator,the locus of arrhythmogenic tissue was assessed with a mean error of 11 mm.Experimental localization of the accessory pathway in a WPW patient was in good agreement with the invasively obtained site.Local repolarization changes were simulated as shortening of the myocytes action potentials in three regions typical for stenosis of main coronary arteries.Using surface QRST integral maps and dipolar source model,small subendocardial and subepicardial lesions of myocardium were inversely located with a mean error of 9 mm and larger transmural lesions with a considerable mean error of 17 mm.Extent and prevalence of subepicardial or subendocardial type of the lesion were reflected in the dipole moment and orientation.In experimental verification of the method,in 7 of 8 patients that underwent PCI of a single vessel,estimated equivalent current dipole position matched well the treated vessel.The results suggest that diagnostic interpretation of body surface potential maps based on dipolar source model could be a useful tool to assess local pathological changes in the heart.
机译:使用高分辨率的体表电位图和心脏生成器的等效电流偶极子模型来评估两种异常情况下的心脏状态:单附件途径WPW综合征和局部心室缺血。该方法的仿真研究和实验验证WPW综合征的单一辅助途径被模拟为房室环的初始心室激活。使用当前的心脏生成器偶极子模型,评估了心律失常组织的位置,平均误差为11 mm在WPW患者中,辅助途径的实验定位与所获得的浸润部位吻合良好。模拟局部复极化变化,以缩短主要冠状动脉狭窄的三个典型区域中的心肌细胞动作电位。偶极源模型,小的心内膜下和心外膜病变心肌的反方向定位,平均误差为9毫米,较大的透壁病变的平均误差为17毫米,在偶极矩和方向上反映了心外膜下或心内膜下类型病变的程度和发生率。方法,在8例接受单血管PCI的患者中,有7例估计等效电流偶极位置与治疗血管吻合良好。结果表明,基于偶极子源模型的体表电位图的诊断解释可能是评估局部电势的有用工具心脏的病理变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号