首页> 外文期刊>European journal of clinical microbiology and infectious diseases: Official publication of the European Society of Clinical Microbiology >Comparative evaluation of two commercial chromogenic media for detection and presumptive identification of urinary tract pathogens.
【24h】

Comparative evaluation of two commercial chromogenic media for detection and presumptive identification of urinary tract pathogens.

机译:两种商业发色培养基用于尿路病原体检测和推定鉴定的比较评估。

获取原文
获取原文并翻译 | 示例
       

摘要

The performance of two commercial chromogenic media for the isolation and presumptive identification of urinary tract pathogens, the CPS ID2 (bioMerieux, France) and the CHROMagar Orientation (BBL Becton Dickinson, USA), was evaluated and compared with that of cystine-lactose-electrolyte-deficient agar and tryptic soy agar with 5% sheep blood. The detection, determination of bacterial counts, and presumptive identification of bacteria causing urinary tract infections were evaluated in 3,000 urine specimens. The two chromogenic media showed excellent correlation with the standard media for the detection and the bacterial count of urinary pathogens. The Escherichia coli strains produced the expected colour on the CHROMagar Orientation and the CPS ID2 media in 99% and 90% of the cases, respectively. The Klebsiella-Enterobacter-Citrobacter and the Proteus-Morganella-Providencia groups were easily identified on both chromogenic media, but further biochemical tests were needed to differentiate them to a species level. Both media enabled the differentiation, with varying degrees of difficulty, of Pseudomonas spp. strains from members of the family Enterobacteriaceae. All isolates of Enterococcus spp. were correctly identified and were easily distinguished from the Streptococcus agalactiae isolates. Staphylococcus saprophyticus isolates were easy to identify only on the CHROMagar Orientation medium. No substantial difference was observed when comparing the results of the susceptibility tests, which were performed according to the standardized disk diffusion method as described by the National Committee for Clinical Laboratory Standards, for colonies recovered from the blood agar versus those recovered from the chromogenic media. In conclusion, the CPS ID2 and CHROMagar Orientation media enabled excellent detection, count determination, and presumptive identification of urinary pathogens, both in pure and mixed cultures, and reliable and accurate antimicrobial susceptibility testing directly from primary isolates. Moreover, these media allowed a remarkable reduction in the workload and a significant savings of time. On the basis of their performance, these media can replace the standard primary plating media used in the routine diagnosis of urinary tract infections.
机译:评估了两种商用发色培养基CPS ID2(法国bioMerieux)和CHROMagar Orientation(美国BBL Becton Dickinson)用于分离和推测尿路病原体的性能,并将其与胱氨酸-乳糖-电解质的性能进行了比较。 -含5%羊血的琼脂和胰蛋白酶大豆琼脂。在3,000份尿液标本中评估了细菌的检测,细菌计数的确定以及可能引起尿路感染的细菌的鉴定。两种生色培养基与尿液病原体检测和细菌计数的标准培养基显示出极好的相关性。大肠杆菌菌株分别在99%和90%的情况下在CHROMagar方向和CPS ID2培养基上产生了预期的颜色。在两种生色培养基上都容易鉴定出克雷伯菌-肠杆菌-柠檬酸杆菌和变形杆菌-摩根氏菌-Providencia组,但是需要进一步的生化测试以将它们区分到一个物种水平。两种培养基均能区分假单胞菌属种,并具有不同程度的难度。肠杆菌科成员的菌株。肠球菌的所有分离株。可以正确鉴定,并且很容易与无乳链球菌分离株区分开。腐生葡萄球菌分离株仅在CHROMagar定向培养基上易于鉴定。当比较敏感性试验的结果时,未观察到实质性差异。敏感性试验是根据国家临床实验室标准委员会描述的标准化圆盘扩散法进行的,对于从血琼脂中回收的菌落与从显色培养基中回收的菌落。总之,CPS ID2和CHROMagar定向培养基可在纯培养和混合培养中实现出色的尿病原体检测,计数测定和推定性鉴定,并直接从主要菌株中进行可靠而准确的抗菌药敏感性测试。此外,这些媒体可以大大减少工作量并节省大量时间。根据它们的性能,这些介质可以代替用于尿路感染常规诊断的标准主要铺板介质。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号