首页> 外文期刊>Bio-medical materials and engineering >A multi-directional wear screening device and preliminary results of UHMWPE articulating against stainless steel.
【24h】

A multi-directional wear screening device and preliminary results of UHMWPE articulating against stainless steel.

机译:一种多向磨损筛分装置以及超高分子量聚乙烯铰接不锈钢的初步结果。

获取原文
获取原文并翻译 | 示例
           

摘要

This paper describes the design of a pin on plate rig which has been modified to give multi-directional motion to the test pins, resulting in elliptical and quasi-elliptical wear paths. Such paths are closer to those seen in vivo by a femoral head articulating against an acetabular cup. The description of the rig is augmented by the results of a test of ultra high molecular weight polyethylene pins rubbing against stainless steel plates. with dilute bovine serum at 37 degrees C being used as the lubricant. With standard reciprocating motion, a mean wear factor of 0.085 x 10(-6) mm3/N m was found, but with multi-directional motion, the mean wear factor increased to 1.10 x 10(-6) mm3/N m, which is very similar to in vivo wear factors.
机译:本文介绍了平板钻机上的销钉的设计,该销钉经过了修改以使测试销钉具有多方向运动,从而导致椭圆形和准椭圆形磨损路径。这种路径更接近于在体内通过股骨头与髋臼杯铰接而看到的路径。对超高分子量聚乙烯销钉在不锈钢板上摩擦的测试结果进一步丰富了该钻机的说明。用37摄氏度的稀牛血清作为润滑剂。在标准往复运动下,平均磨损因子为0.085 x 10(-6)mm3 / N m,但在多向运动下,平均磨损因子增加至1.10 x 10(-6)mm3 / N m,与体内磨损因子非常相似。