摘要

As recently reported, the metal-carbon eutectic points seem to be useful as practical reference points for calibrating thermocouples. The melting temperature of the cobalt-carbon eutectic point (Co-C, is an ideal solution for a reference point being at approximately the middle between the freezing point of copper and the melting point of palladium . In this study, a comparison of reference Co-C cells used for thermocouple calibration service was performed between the Technical Institute of Sweden (SP) and the National Metrology Institute of Japan (NMIJ) by means of two circulating Pt/Pd thermocouples and one circulating Co-C cell in order to investigate the reliability of thermocouple calibration at the Co-C eutectic point. The reference Co-C cell at SP was designed and constructed in the National Physical Laboratory (NPL), and provided to SP, while the reference Co-C cell at NMIJ as well as the circulating cell was designed and constructed at NMIJ. The melting temperature of the reference Co-C cells at SP and NMIJ were evaluated by using the calibrated radiation thermometers at NPL and NMIJ, respectively, prior to the circulation of the thermocouples and the cell between SP and NMIJ. The temperature difference between the reference cells of SP and NMIJ, as measured by means of the circulating thermocouples, was found to be within , while that measured by means of the circulating cell was found to be within . The temperature of reference cells at SP and NMIJ was found to agree within an expanded uncertainty in spite of different temperature traceability chains. This means that the calibration of thermocouples at the Co-C eutectic point was sufficiently reliable.
机译:如最近报道的那样,金属-碳共晶点似乎可用作校准热电偶的实用参考点。钴碳共晶点(Co-C)的熔点温度是理想的解决方案,因为参考点大约在铜的凝固点和钯的熔点之间的中间位置。瑞典技术学院(SP)和日本国家计量学会(NMIJ)之间通过两个循环的Pt / Pd热电偶和一个循环的Co-C电池进行了用于热电偶校准服务的-C电池。 Co-C共晶点处热电偶校准的可靠性:SP的参考Co-C电池是由美国国家物理实验室(NPL)设计和建造的,并提供给SP,而NMIJ的参考Co-C电池以及在NMIJ处设计和构建循环池,在温度t之前,分别使用NPL和NMIJ的校准辐射温度计评估参比Co-C细胞在SP和NMIJ处的熔化温度。 SP和NMIJ之间的热电偶和电池之间的循环。通过循环热电偶测得的SP和NMIJ参比电池之间的温差在以内,而通过循环热电偶测得的温差在以内。尽管温度溯源链不同,但发现SP和NMIJ处参考电池的温度在不确定性扩大范围内保持一致。这意味着在Co-C共晶点处的热电偶校准足够可靠。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号