首页> 外文期刊>British Journal of Radiology >The costs and effects of introducing selectively trained radiographers to an A&E reporting service: a retrospective controlled before and after study.
【24h】

The costs and effects of introducing selectively trained radiographers to an A&E reporting service: a retrospective controlled before and after study.

机译:在A&E报告服务中引入经过选择性培训的射线照相师的成本和效果:研究前后进行回顾性控制。

获取原文
获取原文并翻译 | 示例
           

摘要

The costs and effects of introducing selectively trained radiographers reporting accident and emergency (A&E) radiographs of the appendicular skeleton in a district general hospital were assessed using a retrospective controlled before and after design. Reference standard reports were compared with a random stratified sample of 200 A&E and 200 general practitioner (GP) reports before and after the intervention. GP reports were used as a non-intervention, non-equivalent control group. An A&E specialist registrar judged whether incorrect A&E reports might have a clinically important effect on patient management. The effect of incorrect A&E reports on outcome was assessed by patient re-attendance to the hospital because of missed abnormalities. The annual, average and incremental costs of radiographers and radiologists reporting A&E radiographs were calculated and a sensitivity analysis was undertaken. The introduction of the radiographers resulted in a 1% (95% CI -7.9 to 5.9) fall in A&E radiograph reporting accuracy and 11% (95% CI -33.7 to 11.3) reduction of cases in which incorrect A&E reports might have a clinically important effect on patient management. Only two A&E reports (one before and one after the intervention) affected patient outcome in that a fracture missed at the first visit resulted in patient re-attendance to the X-ray Department. There was a saving of pound361 per annum to the X-ray Department. In conclusion this study provides further evidence that selectively trained radiographers can accurately report A&E plain radiographs and at no additional cost.
机译:在设计之前和之后,通过回顾性对照评估在地区综合医院中引入经选择性培训的放射线照相师报告附件骨骼的事故和紧急情况(A&E)射线照相的成本和效果。在干预前后,将参考标准报告与200份A&E随机分层样本和200份全科医生(GP)报告进行比较。 GP报告被用作非干预,非等效对照组。 A&E专家注册商判断不正确的A&E报告是否可能对患者管理产生重要的临床影响。由于遗漏了异常情况,患者重新就诊,评估了不正确的A&E报告对结果的影响。计算了报告A&E射线照片的射线照相师和放射线医生的年度,平均和增量成本,并进行了敏感性分析。放射技师的介绍导致A&E放射照片报告准确性下降1%(95%CI -7.9至5.9),而错误的A&E报告可能具有临床重要性的病例减少11%(95%CI -33.7至11.3)。对患者管理的影响。只有两份A&E报告(干预之前和之后一份)影响了患者的预后,因为第一次就诊时遗漏了骨折,导致患者需要重新就诊到X射线科。 X射线部门每年节省了361英镑。总之,这项研究提供了进一步的证据,表明经过专门培训的射线照相师可以准确地报告A&E普通射线照相,而无需支付额外费用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号