首页> 外文期刊>British Journal of Radiology >Hepatic bipolar radiofrequency ablation using perfused-cooled electrodes: a comparative study in the ex vivo bovine liver.
【24h】

Hepatic bipolar radiofrequency ablation using perfused-cooled electrodes: a comparative study in the ex vivo bovine liver.

机译:使用灌注冷却电极的肝双极射频消融:离体牛肝的比较研究。

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this paper was to demonstrate the efficacy of the dual probe bipolar radiofrequency (RF) system with the perfused-cooled electrodes inducing coagulation necrosis in the ex vivo bovine liver. The perfused-cooled electrode that allows simultaneous internal cooling and interstitial hypertonic saline perfusion has been developed for RF ablation (RFA). RF was applied to excised bovine liver in a bipolar mode at 150 W using a 200 W generator with two perfused-cooled electrodes for 10 min. After placing the electrodes at 3 cm spacing in the explanted liver, 45 ablation zones were created with three different regimens: Group A, using both intraelectrode cooling and interstitial perfusion; group B, using only the intraelectrode cooling; and group C, using only interstitial perfusion. In groups A and C, RFA was performed with the infusion of 6% hypertonic saline at the rate of 2 ml min(-1). During RFA, we measured the tissue temperature at the midpoint between the two electrodes. The dimensions ofthe ablation zones and the changes in impedance, currents and liver temperature during RFA were compared in these three groups. The mean tissue impedance during RFA in group A (56.7+/-21.7 Omega) and group C (56.9+/-20.6 Omega) was significantly lower than group B (112+/-19.7 Omega) (p<0.001). The mean current was higher in group A (1765+/-128 mA) than groups B (760+/-321 mA) and C (1298+/-349 mA) (p<0.05). In addition, the shortest vertical diameter of coagulation necrosis was greater in groups A (4.9+/-0.5 cm) and C (4.6+/-0.7 cm) than in group B (3.5+/-0.4 cm) (p<0.05). The temperature at the mid-point between the two probes was higher in group A than other groups: 99 degrees C in group A, 88.9 degrees C in group B, and 94.3 degrees C in group C (p>0.05). The ratios of the diameter of the long-axis to the diameter of the vertical-axis of groups A, B and C were 1.1+/-0.1, 1.2+/-0.1, and 1.1+/-0.2, respectively (p<0.05). Bipolar RFA using intraelectrode cooling and the interstitial saline perfusion simultaneously produced ablation zones significantly larger than the area produced by only one measure.
机译:本文的目的是证明带有灌注冷却电极的双探针双极射频(RF)系统在离体牛肝中诱导凝血坏死的功效。允许同时进行内部冷却和间质性高渗盐水灌注的灌注冷却电极已开发用于射频消融(RFA)。使用带有两个灌注冷却电极的200 W发生器,以150 W的双极模式将RF应用于双侧切除的牛肝,持续10分钟。将电极以3 cm的间距放置在移植肝脏中后,采用三种不同的方案创建了45个消融区:A组,使用电极内冷却和间质灌注; B组,仅使用电极内冷却; C组,仅使用间质灌注。在A组和C组中,以2 ml min(-1)的速度输注6%高渗盐水进行RFA。在RFA期间,我们在两个电极之间的中点测量了组织温度。比较了三组射频消融术中消融区的大小以及阻抗,电流和肝脏温度的变化。 A组(56.7 +/- 21.7 Omega)和C组(56.9 +/- 20.6 Omega)在RFA期间的平均组织阻抗显着低于B组(112 +/- 19.7 Omega)(p <0.001)。 A组(1765 +/- 128 mA)的平均电流高于B组(760 +/- 321 mA)和C组(1298 +/- 349 mA)(p <0.05)。此外,A组(4.9 +/- 0.5 cm)和C组(4.6 +/- 0.7 cm)的最短凝结坏死垂直直径大于B组(3.5 +/- 0.4 cm)(p <0.05) 。 A组中两个探针之间的中点温度高于其他组:A组为99℃,B组为88.9℃,C组为94.3℃(p> 0.05)。 A,B和C组的长轴直径与垂直轴直径之比分别为1.1 +/- 0.1、1.2 +/- 0.1和1.1 +/- 0.2(p <0.05 )。使用电极内冷却和间质盐水灌注的双极RFA同时产生的消融区明显大于仅采用一种措施产生的面积。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号