Reduction in patient skin dose during interventional radiology with the use of an air gap substitute.

机译:使用气隙替代物可减少介入放射期间的患者皮肤剂量。

获取原文
获取原文并翻译 | 示例
           

摘要

Scattered radiation is inevitably generated in the patient couch during interventional radiology (IVR) procedures that use an under-couch tube system. Most of this scatter reaches the patient's skin surface and results in an increase in the skin dose without contributing to the diagnostic image. We considered that this unnecessary exposure could be reduced by the addition of an air gap between the couch and the patient. Because it is physically impossible to place an air gap on top of the couch and under the patient, we devised a new process in which an expanded polystyrene (EPS; rho = 0.0125 g cm(-3)) board is used as a substitute for the air gap. The results show that the EPS board played an effective role in reducing the skin dose to the patient. Using an EPS board 6 cm thick as an air gap substitute resulted in skin dose savings of approximately 9%. This method is easy to set up in clinical circumstances and is inexpensive. We recommend that this simple method of skin dose reduction be used for all IVR procedures.
机译:在使用床下导管系统的介入放射学(IVR)程序中,不可避免地在患者卧榻中产生散射辐射。这种散射大部分都到达患者的皮肤表面,导致皮肤剂量增加,而无助于诊断图像。我们认为,可以通过在沙发和患者之间增加空气间隙来减少这种不必要的暴露。由于从物理上讲不可能在沙发上和患者下方放置气隙,因此我们设计了一种新工艺,其中使用膨胀聚苯乙烯(EPS; rho = 0.0125 g cm(-3))板代替气隙。结果表明,EPS板在减少患者皮肤剂量方面发挥了有效作用。使用6厘米厚的EPS板作为气隙替代品可节省大约9%的皮肤剂量。该方法易于在临床环境中建立并且便宜。我们建议将这种简单的减少皮肤剂量的方法用于所有IVR程序。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号