【24h】

Effect of convergence angle on impactor performance

机译:Effect of convergence angle on impactor performance

获取原文
获取原文并翻译 | 示例
           

摘要

Two nozzles, modified and original, were tested in a sampler that was placed in a wind tunnel and penetration efficiencies, root Stk50, and slope of the performance curve were determined by challenging the sampler with fluorescent-tagged monodisperse test aerosol particles having known concentration. It was shown that a change in convergence angle of the modified nozzle can affect impactor performance. The root Stk50 for original and modified nozzles were 0.57 and 0.49, respectively. The slope of the efficiency curve for original and modified nozzles was 1.52 and 1.36, respectively.