...
首页> 外文期刊>Analytical and bioanalytical chemistry >Determination of free cortisol and free cortisone in human urine by on-line turbulent flow chromatography coupled to fused-core chromatography–tandem mass spectrometry (TFC–HPLC–MS/MS)
【24h】

Determination of free cortisol and free cortisone in human urine by on-line turbulent flow chromatography coupled to fused-core chromatography–tandem mass spectrometry (TFC–HPLC–MS/MS)

机译:Determination of free cortisol and free cortisone in human urine by on-line turbulent flow chromatography coupled to fused-core chromatography–tandem mass spectrometry (TFC–HPLC–MS/MS)

获取原文
获取原文并翻译 | 示例
           

摘要

Urinary free cortisol and urinary free cortisone are decisive markers for the diagnosis of syndromes related to the dysfunction of the adrenal gland or to evaluate certain enzymatic disorders. Here, we present a new method, designed for routine laboratory use, which enables quick determination of these analytes with minor sample workup. Turbulent flow chromatography shortens sample preparation, and connection to a fused-core particle-packed column (rugged amideembedded C18 phase) permits a rapid and effective separation of the analytes, as well as additional separation from other related and isobaric compounds present in urine. Urinary isobaric compounds were successfully identified. The method requires only 100 μl of urine supernatant per sample. The total time between injections is 9.5 min. The solvents used for both turbulent and analytical chromatography are water and methanol, and the relatively low flows needed during the method resulted in an extended life of the columns. Linearity showed a R2>0.994. Limit of detection and limit of quantification are 0.5 and 1.0 ng/ml for cortisone and 1.0 and 2.0 ng/ml for cortisol. Recoveries ranged from99.7 to 109.1for cortisone and from 98.7 to 102.9 for cortisol. Accuracy values(relative errors) for intra- and inter-assay experiments were always below 8 , whereas precision (percent CV) ranged from 3.7 to 10.7. Nomatrix effects were detected during the validation process. The reproducibility for each analyte's retention time was excellent, with a coefficient of variation always below 0.2 . The final validation step included the study of urine samples from healthy children and from children previously diagnosed with corticoidal disorders. The high selectivity achieved enables quick data handling.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号