首页> 外文期刊>IEICE transactions on information and systems >Kalman-Filtering-Based Joint Angle Measurement with Wireless Wearable Sensor System for Simplified Gait Analysis
【24h】

Kalman-Filtering-Based Joint Angle Measurement with Wireless Wearable Sensor System for Simplified Gait Analysis

机译:Kalman-Filtering-Based Joint Angle Measurement with Wireless Wearable Sensor System for Simplified Gait Analysis

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study is to realize a simplified gait analysis system using wearable sensors. In this paper, a joint angle measurement method using Kalman filter to correct gyroscope signals from accelerom-eter signals was examined in measurement of hip, knee and ankle joint angles with a wireless wearable sensor system, in which the sensors were attached on the body without exact positioning. The lower limb joint angles of three healthy subjects were measured during gait with the developed sensor system and a 3D motion measurement system in order to evaluate the measurement accuracy. Then, 10 m walking measurement was performed under different walking speeds with a healthy subject in order to find the usefulness of the system as a simplified gait analysis system. The joint angles were measured with reasonable accuracy, and the system showed joint angle changes that were similar to those shown in a previous report as walking speed changed. It would be necessary to examine the influence of sensor attachment position and method for more stable measurement, and also to study other parameters for gait evaluation.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信