首页> 外文期刊>jacc: clinical electrophysiology >Development, Preclinical Validation, and Clinical Translation of a Cardiac Magnetic Resonance - Electrophysiology System With Active Catheter Tracking for Ablation of Cardiac Arrhythmia
【24h】

Development, Preclinical Validation, and Clinical Translation of a Cardiac Magnetic Resonance - Electrophysiology System With Active Catheter Tracking for Ablation of Cardiac Arrhythmia

机译:Development, Preclinical Validation, and Clinical Translation of a Cardiac Magnetic Resonance - Electrophysiology System With Active Catheter Tracking for Ablation of Cardiac Arrhythmia

获取原文
           

摘要

© 2017 American College of Cardiology FoundationObjectives This study sought to develop an actively tracked cardiac magnetic resonance-guided electrophysiology (CMR-EP) system and perform first-in-human clinical ablation procedures. Background CMR-EP offers high-resolution anatomy, arrhythmia substrate, and ablation lesion visualization in the absence of ionizing radiation. Implementation of active tracking, where catheter position is continuously transmitted in a manner analogous to electroanatomic mapping (EAM), is crucial for CMR-EP to take the step from theoretical technology to practical clinical tool. Methods The setup integrated a clinical 1.5-T scanner, an EP recording and ablation system, and a real-time image guidance platform with components undergoing ex vivo validation. The full system was assessed using a preclinical study (5 pigs), including mapping and ablation with histological validation. For the clinical study, 10 human subjects with typical atrial flutter (age 62 ± 15 years) underwent MR-guided cavotricuspid isthmus (CTI) ablation. Results The components of the CMR-EP system were safe (magnetically induced torque, radiofrequency heating) and effective in the CMR environment (location precision). Targeted radiofrequency ablation was performed in all animals and 9 (90) humans. Seven patients had CTI ablation completed using CMR guidance alone; 2 patients required completion under fluoroscopy, with 2 late flutter recurrences. Acute and chronic CMR imaging demonstrated efficacious lesion formation, verified with histology in animals. Anatomic shape of the CTI was an independent predictor of procedural success. Conclusions CMR-EP using active catheter tracking is safe and feasible. The CMR-EP setup provides an effective workflow and has the potential to change the way in which ablation procedures may be performed.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号