首页> 外文期刊>Atomic Spectroscopy >Determination of As, Bi, Cd, Co, Cr, Ga, In, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, and V in antihypertensive drugs by inductively coupled plasma mass spectrometry
【24h】

Determination of As, Bi, Cd, Co, Cr, Ga, In, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, and V in antihypertensive drugs by inductively coupled plasma mass spectrometry

机译:电感耦合等离子体质谱法测定降压药中As,Bi,Cd,Co,Cr,Ga,In,Mn,Ni,Pb,Sb,Se,Sn,Te,Tl和V

获取原文
获取原文并翻译 | 示例
           

摘要

A rapid procedure for the determination of As-75, Cd-114, 59Co Mn-55 Ni-58 V-51, Sn-120 Sb-123 Bi-209 Ga-69 In-115 Se-78 Te-130 Tl-205 Pb-208 and Cr-52 in antihypertensive drugs by inductively coupled plasma mass spectrometry (ICP-MS) is proposed. For these determinations the samples were prepared by a simple, fast extraction method with concentrated nitric acid. The optimization of plasma conditions, such as radiofrequency (RF) and nebulization gas flow rate, according to the manufacturer, was compared to a multivariate design (MD) optimization. The values obtained for the slopes and the correlation coefficients in the MD for all studied isotopes showed that the central point (1000 W and 1.0 L min(-1)) was the best condition and very close to the ones obtained in the optimization recommended by the manufacturer; therefore the following studies were made using the latter optimization. Calibration was performed by matrix matching with an r(2) higher than 0.99 for all isotopes investigated. The limits of detection and quantification ranged from 0.01 to 1.41 mu g L-1 for Tl-205 and Bi-209, and from 0.03 and 4.69 mu g L-1 for Se-78. Intra-assay studies (n=7 for each level) on the samples spiked with 0.1, 5.0, and 20.0 mu g L-1 of the isotopes of interest showed a coefficient of variation ranging from 0.3% to 10.9%. Recovery studies on the drug spiked with four levels (0.1, 2.0, 5.0, and 20.0 mu g L-1; n=3 for each level) showed recoveries between 96.5 +/- 1.6% and 115.5 +/- 7.5%. Seventy antihypertensive drug samples were analyzed and the results range from 0.03 to 4087.6 ng per capsule or tablet.
机译:快速测定As-75,Cd-114、59Co Mn-55 Ni-58 V-51,Sn-120 Sb-123 Bi-209 Ga-69 In-115 Se-78 Te-130 Tl-205的快速方法提出了电感耦合等离子体质谱法(ICP-MS)用于降压药中的Pb-208和Cr-52的研究。对于这些测定,样品是通过简单,快速的浓硝酸萃取方法制备的。根据制造商的说法,将等离子体条件的优化(例如射频(RF)和雾化气体流速)与多变量设计(MD)优化进行了比较。对于所有研究的同位素,获得的斜率值和MD的相关系数表明,中心点(1000 W和1.0 L min(-1))是最佳条件,并且非常接近于推荐的最优化条件。生产厂家;因此,使用后一种优化方法进行了以下研究。通过对所有研究同位素的r(2)都高于0.99的矩阵匹配进行校准。对于Tl-205和Bi-209,检测和定量的极限范围为0.01至1.41μgL-1,对于Se-78,检测和定量限为0.03至4.69μgL-1。对掺有0.1、5.0和20.0μg L-1感兴趣同位素的样品进行的测定内研究(每个水平n = 7)显示变异系数为0.3%至10.9%。对掺入四个水平(0.1、2.0、5.0和20.0μg L-1;每个水平n = 3)的药物的回收率研究表明,回收率在96.5 +/- 1.6%和115.5 +/- 7.5%之间。分析了七十个降压药样品,每个胶囊或片剂的结果范围为0.03至4087.6 ng。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号