...
首页> 外文期刊>Applied occupational and environmental hygiene >Folpet permeation through nitrile gloves.
【24h】

Folpet permeation through nitrile gloves.

机译:通过丁腈手套使地毯渗透。

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to investigate whether two different brands of unsupported and unlined nitrile gloves protected against aqueous emulsions of a Folpet wettable powder (50% Folpet) using an ASTM type-I-PTC 600 permeation cell at 30.0 +/- 0.1 degrees C held in a shaking water bath. An analytical method to determine Folpet using the internal standard method was first developed based on gas chromatography-mass spectrometry (GC-MS), and gas chromatography-electron capture detection (GC-ECD). A novel pyrolysis GC-ECD technique that quantified the thermal degradation product phthalimide had pg sensitivity suitable to detect the trace amounts of Folpet that permeated. The on-column conversion was (68.0 +/- 9.5) percent at 170 degrees C over the folpet injected mass range of 3 to 148 pg. The challenge solution in the permeation cell was 1.4 mg/mL aqueous emulsion of Folpet wettable powder, and 2-propanol was the collection solvent. After evaporation of the collection solvent, the time weighted average rate of permeation of Folpet through SafeSkin nitrile (an exams type of glove) after 8 hours was (42.1 +/- 2.9) ng/cm(2)/min compared with (2.04 +/- 0.69) ng/cm(2)/min for the Sol-Vex nitrile (industrial chemical resistant), the latter being about 21 times more protective and also near the limits of detection. The respective values after 4 hours of exposure were (28.4 +/- 1.2) and (0.65 +/- 0.36) ng/cm(2)/min. Diagnostic reflectance infrared minima of both challenge and collection sides of the gloves showed small changes in wave number and intensity values after 8 hours of exposure, with Folpet being detected in dried spots on the challenge side. GC-ECD-based permeation and IR reflectance data indicated high chemical resistance of the Sol-Vex gloves to an aqueous emulsion of Folpet.
机译:这项研究的目的是调查使用ASTM I-PTC 600渗透池在30.0 +/- 0.1度下,两个不同品牌的无支撑和无衬里丁腈手套是否可以保护Folpet可湿性粉剂(50%Folpet)的水乳液。 C保持在摇动的水浴中。首先基于气相色谱-质谱(GC-MS)和气相色谱-电子捕获检测(GC-ECD),开发了使用内标法测定福尔佩特的分析方法。定量热降解产物邻苯二甲酰亚胺的新型热解GC-ECD技术具有pg灵敏度,适合检测痕量的Folpet渗透。在170℃下,经Folpet注入的3至148 pg的质量范围,柱上转化率为(68.0 +/- 9.5)%。渗透池中的攻击溶液为1.4 mg / mL Folpet可湿性粉剂的水性乳液,2-丙醇为收集溶剂。蒸发收集溶剂后,8小时后Folpet通过SafeSkin腈(一种手套的检查类型)渗透的时间加权平均速率为(42.1 +/- 2.9)ng / cm(2)/ min,而(2.04 + /-0.69)ng / cm(2)/ min的Sol-Vex腈(工业化学耐性),后者的防护性约为21倍,并且也接近检测极限。暴露4小时后的各自值为(28.4 +/- 1.2)和(0.65 +/- 0.36)ng / cm(2)/ min。手套的挑战面和收集面的诊断反射红外最小值都显示了暴露8小时后波数和强度值的微小变化,在挑战面的干燥点中检测到Folpet。基于GC-ECD的渗透率和红外反射率数据表明,Sol-Vex手套对Folpet水性乳液的耐化学性很高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号