Thermocouples are often used for temperature measurements in heat exchangers. However if the radiation losses from a thermocouple in a high temperature gas flow to colder surroundings are ignored significant errors can occur. Even at moderate temperature differences, these can be significant. Prediction of radiation losses from theory can be problematic, especially in situations where there are large variations in the measured temperatures as the emissivity and radiative heat transfer coefficient of the thermocouple are not constant. The following approach combines experimental results with established empirical relationships to estimate losses due to radiation in an annular heat exchanger at temperatures up to 950℃.
机译:热电偶通常用于热交换器中的温度测量。但是,如果忽略了从高温气流中的热电偶到较冷环境的辐射损失,则可能会发生重大错误。即使在温差适中,这些差异也可能很大。从理论上预测辐射损失可能会有问题,尤其是在由于热电偶的发射率和辐射传热系数不恒定而导致测量温度存在较大变化的情况下。以下方法将实验结果与已建立的经验关系结合起来,以估算由于环形热交换器在高达950℃的温度下的辐射而造成的损失。