首页> 外文期刊>Journal of instrumentation: an IOP and SISSA journal >The BELLE Electromagnetic Calorimeter and its Upgrade to BelleII
【24h】

The BELLE Electromagnetic Calorimeter and its Upgrade to BelleII

机译:Belle电磁热量及其升级到Belleii

获取原文
获取原文并翻译 | 示例
           

摘要

The newSuperKEKB collider will be an upgrade of the existingKEKBelectron-positron asymmetric machine, with a target luminosity of 8 × 10~(35) cm~(-2)s~(-1), about 40 times greater than the previous one. The accelerator upgrade is based on the novel low-emittance "nanobeams" scheme. The detector will also be upgraded to cope with the higher luminosity, pile-up and occupancy. We report on the development of the new pure CsI calorimeter for the forward region. An intensive R&D has been carried out to study the performance of pure CsI crystals with Large Area Avalanche Photodiodes readout (LAAPD). Results on the signal to noise ratio for different sensors and front end electronics configurations will be presented as well as the use of filters and wavelength shifters. Measurements with a source, simulating the background machine, have been performed and will also be presented.
机译:Newsuperkekb对撞机将是现有的Kekbelectron-Positron不对称机器的升级,目标发光度为8×10〜(35)CM〜(-2)S〜(-1),大约是前一台的40倍。 加速器升级基于新型的低电压“纳米梁”方案。 检测器还将升级以应对较高的发光度,堆积和占用率。 我们报告了向前区域的新纯CSI量热仪的开发。 已经进行了密集的研发,以研究具有大面积雪崩光电二极管读数(LAAPD)的纯CSI晶体的性能。 将介绍不同传感器和前端电子配置的信号与噪声比的结果,以及使用过滤器和波长变速杆的使用。 用源进行测量,模拟背景计算机,也将展示。