This study aims to understand radiological protection systems in diagnostic radiology practices among 30 diagnostic radiology facilities in Mumbai, India. It assesses the status of radiological protection systems in the facilities, continuous professional development (CPD) of workers and their risky working behaviour and perceptions using a semi-structured questionnaire. Then, we examine the perceptions of workers when they were working in facilities without proper protection systems. We also, attempt to understand the reasons why workers engage in risky behaviour despite the availability of protective systems. In doing so, we examine the influence of CPD on their work behaviour. The study observed that about 20% of the diagnostic radiology facilities in Mumbai had lack of implementation of the regulatory requirements and establishment of radiological protection systems. Obviously, it is expected that the workers of regulated facilities would comply with regulatory requirements, and their working behaviour would be better than those of their counterparts of unregulated facilities would. However, our study observes that some workers in the regulated practices also indulge in risky working behaviour. About 30% of workers were not using personal monitoring device during work procedures. Although lead aprons were available in the facilities, about 51% of workers were not wearing it wherever required. It was observed that about 10% of workers engaged in the activities like opening the door during radiation exposure, chatting with others on mobile phone during procedure and not checking collimator light before radiation exposure etc. The factors that contributed to workers' engagement in risky work behaviour are the non-availability of protection systems, lack of exposure to CPD, low-risk perception of workers and dearth of communication between institutes and regulator.
机译:本研究旨在了解印度孟买30家放射诊断机构在放射诊断实践中的辐射防护系统。它使用半结构化问卷评估设施中辐射防护系统的状态、工人的持续专业发展(CPD)以及他们的危险工作行为和看法。然后,我们考察了工人在没有适当保护系统的设施中工作时的感受。我们还试图理解,尽管有保护系统,工人仍会从事危险行为的原因。在此过程中,我们考察了持续专业发展对他们工作行为的影响。该研究发现,孟买约20%的放射诊断设施缺乏监管要求的实施和辐射防护系统的建立。显然,预计受监管设施的工人将遵守监管要求,他们的工作行为将优于非监管设施的工人。然而,我们的研究发现,一些受监管的工人也沉迷于危险的工作行为。大约30%的工人在工作过程中没有使用个人监控设备。虽然工厂里有铅围裙,但约51%的工人没有在需要的地方穿铅围裙。据观察,约有10%的工人从事的活动包括在辐射暴露期间打开门、在操作过程中与他人通过手机聊天以及在辐射暴露前不检查准直器光线等。导致工人从事危险工作行为的因素包括没有防护系统、没有接触CPD、,员工的低风险认知,以及机构和监管机构之间缺乏沟通。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号