首页> 外文期刊>The Journal of arthroplasty >Interobserver and Intraobserver Reliability of Three-Dimensional Preoperative Planning Software in Total Hip Arthroplasty
【24h】

Interobserver and Intraobserver Reliability of Three-Dimensional Preoperative Planning Software in Total Hip Arthroplasty

机译:Interobserver和IntraObserver Total Hip关节置换术中的三维术前计划软件的可靠性

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract Background The purpose of this study is to clarify interobserver and intraobserver reliabilities of the three-dimensional (3D) templating of total hip arthroplasty (THA). Methods We selected preoperative computed tomography from 60 hips in 46 patients (14 men and 32 women) who underwent primary THA. To evaluate interobserver and intraobserver reliability, 6 orthopedic surgeons performed 3D templating twice over a 4-week interval. We investigated intraclass correlation coefficients (ICCs) and percent agreement of component size and alignment, comparing morphological differences in the hip. Reproducibility was also compared between groups with osteoarthritis (OA) and those with osteonecrosis (ON). Results The interobserver reliabilities for mean cup size and stem size were excellent, with ICC?= 0.907 and 0.944, respectively. The value was significantly higher in the ON group than in the OA group. In the OA group, the reliability of cup size and alignment decreased in hips with severe subluxation. Percent agreement of stem size was significantly different between the shapes of femoral canal. For intraobserver reliability, the mean ICC of cup size was 0.965 overall, while the value in the ON group was significantly higher than in the OA group. The mean ICC of stem size was 0.972 overall. Conclusion Computed tomography–based 3D templating showed excellent reliability for component size and alignment in THA. Deformity of the affected joint influenced the reliability of preoperative planning.
机译:摘要背景本研究的目的是阐明全髋关节置换术(THA)三维模板的观察者间和观察者内的可靠性。方法选择46例(14男32女)60髋行全髋关节置换术患者的术前计算机断层扫描。为了评估观察者之间和观察者内部的可靠性,6名整形外科医生在4周的时间间隔内进行了两次3D模板制作。我们研究了组内相关系数(ICC)和组件大小和对齐的一致性百分比,比较了髋关节的形态学差异。还比较了骨关节炎(OA)组和骨坏死(ON)组之间的重复性。结果观察者之间对平均杯大小和茎大小的可靠性良好,ICC?=分别为0.907和0.944。ON组的值明显高于OA组。在OA组中,严重半脱位的髋部杯大小和对齐的可靠性降低。股骨柄大小的一致性百分比在股骨管形状之间存在显著差异。对于观察者内部的可靠性,杯子大小的平均ICC总体为0.965,而ON组的ICC值显著高于OA组。总的来说,茎大小的平均ICC为0.972。结论基于计算机断层扫描的3D模板显示THA中部件尺寸和对齐的良好可靠性。受影响关节的畸形影响术前计划的可靠性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号