...
首页> 外文期刊>Injury >Arthroscopically measured syndesmotic stability after screw vs. suture button fixation in a cadaveric model
【24h】

Arthroscopically measured syndesmotic stability after screw vs. suture button fixation in a cadaveric model

机译:在尸体模型中螺钉与缝合缝按钮固定后的关节镜下测量的Syndesmotic稳定性

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract Background Appropriate management of ankle syndesmotic instability is needed to prevent the development of complications. Previous biomechanical studies have evaluated movement of the fibula after screw or suture button fixations with different results, most likely being caused by variations in experimental setups that did not mirror the in vivo clinical setting. This study aimed to arthroscopically compare in a cadaveric model the stability of syndesmotic fixation with either a suture button or syndesmotic screw. Methods Eight fresh matched pairs of human ankle cadaver specimens (above knee) underwent arthroscopic assessment with (1) intact ligaments, (2) after complete disruption, and (3) after repair with either a quadracortical syndesmotic screw or suture button construct. In every stage, four loading conditions were considered under 100N of direct force: 1) unstressed, 2) lateral hook test, 3) anterior to posterior (AP) translation test, and 4) posterior to anterior (PA) translation test. Coronal plane tibiofibular diastasis, as well as sagittal plane tibiofibular translation, were arthroscopically measured. Results Coronal plane anterior and posterior tibiofibular diastasis and sagittal plane tibiofibular translation were measured using probes of increasing diameters. Following screw fixation, syndesmotic stability was similar to the uninjured syndesmosis in the coronal plane (anterior, median 0.0mm [IQR 0.0–0.3] vs. 0.3mm [IQR 0.2–0.3]; p=0.57; posterior, median 0.1mm [IQR 0.0–0.4] vs. 0.2mm [IQR 0.1–0.3]; p=1.0) but more rigid in the sagittal plane (median 0.0mm [IQR 0.0–0.1] vs. 1.0mm [IQR 0.4–1.5]; p=0.012). Repairing the unstable syndesmosis with a suture button construct resulted in coronal plane stability similar to the uninjured syndesmosis (anterior, median 0.2mm [IQR 0.1–0.3] vs. 0.2mm [IQR 0.1–0.3]; p=0.48; posterior, median 0.2mm [IQR 0.1–0.3] vs. 0.3mm [IQR 0.1–0.5]; p=0.44). However, sagittal plane fibular motion remained unstable as compared to the uninjured syndesmosis (median 2.2mm [IQR 1.6–2.6] vs. 0.8mm [IQR 0.4–1.3]; p=0.012). Conclusion Current fixation methods for syndesmotic disruption maintain coronal plane fibular stability. Screw and suture button constructs, however, respectively resulted in greater or insufficient constraint to fibular motion in the sagittal plane as compared to the intact syndesmotic ligament. These findings suggest that neither traditional screw nor suture button fixations optimally stabilize the syndesmosis, which may have implications for postoperative care and clinical outcomes.
机译:None

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号