首页> 外文期刊>Analytical and bioanalytical chemistry >Column-switching high-performance liquid chromatography electrospray mass spectrometry coupled with on-line of extraction for the determination of mono- and di-(2-ethylhexyl) phthalate in blood samples
【24h】

Column-switching high-performance liquid chromatography electrospray mass spectrometry coupled with on-line of extraction for the determination of mono- and di-(2-ethylhexyl) phthalate in blood samples

机译:柱切换高效液相色谱电喷雾质谱联用萃取在线测定血液样品中邻苯二甲酸单和二(2-乙基己基)酯

获取原文
获取原文并翻译 | 示例
           

摘要

A novel method based on column-switching high-performance liquid chromatography-electrospray mass spectrometry (LC-MS) coupled with an on-line extraction column containing conjugated avidin has been developed for direct injection analysis of di(2-ethylhexyl) phthalate (DEHP) and its metabolite, mono(2-ethylhexyl) phthalate (MEHP), in blood samples. The sample preparation for on-line extraction involved the mixing of blood samples with internal standards, DEHP-d_4 and MEHP-d_4, in LC glass vials. A linear response was found for column-switching LC-MS when tests were conducted within the validated range of 25 to 1000 ng mL~(-1) for DEHP and 5 to 1000 ng mL~(-1) for MEHP, with correlation coefficients (r) greater than 0.999. In addition, the recoveries of DEHP and MEHP from human plasma were calculated by using this method with on-line extraction, yielding recoveries of up to 91.2% (RSD<5%). We measured the background levels of DEHP and MEHP in six human plasma samples from healthy volunteers and three fetal bovine serum samples for cell-line culture. DEHP and MEHP were not detected in all human plasma samples (N.D. is <25 ng mL~(-1) for DEHP, and N.D. is <5.0 ng mL~(-1) for MEHP). In contrast, high DEHP contamination of commercially available fetal bovine serum samples was found by this method.
机译:开发了一种基于柱切换高效液相色谱-电喷雾质谱(LC-MS)和包含共轭抗生物素蛋白的在线萃取柱的新方法,用于直接进样分析邻苯二甲酸二(2-乙基己基)酯(DEHP) )及其代谢物,血样中的邻苯二甲酸单(2-乙基己基)酯(MEHP)。用于在线提取的样品制备涉及将血液样品与内标物DEHP-d_4和MEHP-d_4在LC玻璃小瓶中混合。在DEHP和MEHP的验证范围分别为25至1000 ng mL〜(-1)和MEHP的验证范围为5至1000 ng mL〜(-1)范围内进行测试时,发现柱切换LC-MS的线性响应(r)大于0.999。此外,使用此方法在线提取可计算出人血浆中DEHP和MEHP的回收率,回收率高达91.2%(RSD <5%)。我们在来自健康志愿者的六个人血浆样品和三个用于细胞系培养的胎牛血清样品中测量了DEHP和MEHP的背景水平。在所有人类血浆样品中均未检测到DEHP和MEHP(DEHP的N.D. <25 ng mL〜(-1),MEHP的N.D. <5.0 ng mL〜(-1))。相反,通过这种方法发现了市售胎儿牛血清样品的高DEHP污染。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号