...
首页> 外文期刊>British Journal of Radiology >The effect of capped biparametric magnetic resonance imaging slots on weekly prostate cancer imaging workload.
【24h】

The effect of capped biparametric magnetic resonance imaging slots on weekly prostate cancer imaging workload.

机译:封盖的双轴磁共振成像槽对每周前列腺癌成像工作量的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

Objective: To introduce capped biparametric (bp) MRI slots for follow-up imaging of prostate cancer patients enrolled in active surveillance (AS) and evaluate the effect on weekly variation in the number of AS cases and total MRI workload. Methods: Three 20min bpMRI AS slots on two separate days were introduced at Addenbrooke's Hospital, Cambridge. The weekly numbers of total prostate MRIs and AS cases recorded 15 months before and after the change (Groups 1 and 2, respectively). An intergroup variation in the weekly scan numbers was assessed using the coefficient of variance (CV) and mean absolute deviation; the Mann-Whitney U test was used for an intergroup comparison of the latter. Results: In AS patients, a shift from considerable to moderate variation in weekly scan numbers was observed between the two groups (CV, 51.7 and 26.8%, respectively); mean absolute deviation of AS scans also demonstrated a significant decrease in Group 2 (1.28 vs 2.58 in Group 1; p < 0.001). No significant changes in the variation in total prostate MRIs were observed, despite a 10% increased workload in Group 2. Conclusion: A significant reduction in weekly variation of AS cases was demonstrated following the introduction of capped bpMRI slots, which can be used for more accurate long-term planning of MRI workload. Advances in knowledge: The paper illustrates the potential of introducing capped AS MRI slots using a bp protocol to reduce weekly variation in demand and allow for optimising workflow, which will be increasingly important as the demands on radiology departments increase worldwide.
机译:目的:引入封端的双轴(BP)MRI插槽,用于纳入主动监测(AS)的前列腺癌患者的后续成像,评价与病例数量和总MRI工作量的每周变化的影响。方法:在剑桥Addenbroke的医院引入了两个单独的日子的三个20min BPMRI作为插槽。总前列腺MRIS的每周数量以及在变更前和之后的15个月内记录的情况(分别为1和2组)。使用方差系数(CV)和平均绝对偏差来评估每周扫描号的帧间组变化。 Mann-Whitney U测试用于后者的互动比较。结果:作为患者,在两组(CV,51.7和26.8%之间,观察到每周扫描数量相当于适度变化的转变;平均扫描的绝对偏差也表明,第2组(1.28 Vs 2.58中的1; p <0.001)。在第2组工作量增加10%的工作量增加了10%的情况下,没有观察到总前列腺MRI的变化的显着变化。结论:在引入封端的BPMRI槽后,每周变化的显着减少,可用于更多MRI工作量的准确长期规划。知识的进步:本文说明了使用BP协议引入作为MRI插槽的潜力,以减少需求的每周变化,并允许优化工作流程,这将随着对全球的需求越来越重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号