Parallelism as a novel marker for structural integrity of retinal layers in optical coherence tomographic images in eyes with epiretinal membrane

机译:平行性是视网膜前膜眼睛光学相干断层扫描图像中视网膜层结构完整性的新标志

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose To propose a new parameter, "Parallelism," to evaluate retinal layer integrity on spectral-domain optical coherence tomography (SDOCT), and to investigate the association between parallelism and visual function in eyes with idiopathic epiretinal membrane (ERM). Design Retrospective, observational evaluation of a diagnostic test. Methods We evaluated a consecutive series of 57 eyes of 57 patients with ERM and 30 healthy eyes of 30 volunteers for whom M-CHARTS testing and SDOCT were performed on the same day. OCT images were skeletonized, and the orientation of segmented lines in the image was termed "Parallelism" and was expressed as a value ranging from 0-1 and increasing as the retinal layers ran more parallel with each other. The relationships between parallelism and visual acuity and between parallelism and metamorphopsia score were evaluated. Results In normal eyes, parallelism was nearly homogeneous and varied slightly with the location. Parallelism in eyes with ERM was significantly lower than that in normal eyes. In the horizontal and vertical scans, parallelism was significantly correlated with visual acuity, horizontal metamorphopsia score, and vertical metamorphopsia score. Parallelism of the center (1 mm) in the horizontal scan was strongly correlated with horizontal metamorphopsia score (R = -0.632; P <.0001). Significant negative correlation was found between parallelism and retinal thickness both in horizontal and vertical scans. Conclusions Parallelism was significantly lower in eyes with ERM than in normal eyes, and correlated strongly with metamorphopsia and visual acuity in eyes with ERM.
机译:目的提出一个新参数“平行度”,以评估光谱域光学相干断层扫描(SDOCT)上的视网膜层完整性,并研究特发性视网膜前膜(ERM)眼睛的平行度与视觉功能之间的关系。设计对诊断测试进行回顾性,观察性评估。方法我们评估了57例ERM患者的57眼连续系列和30例志愿者的30眼健康眼睛,他们在同一天进行了M-CHARTS测试和SDOCT。 OCT图像被骨架化,图像中分段线的方向称为“平行度”,并表示为0-1范围内的值,并且随着视网膜层彼此之间的平行度增加而增加。评价了平行度和视敏度之间的关系以及平行度和变态评分之间的关​​系。结果在正常的眼睛中,平行度几乎是均匀的,并且随位置而略有变化。 ERM眼的平行度明显低于正常眼。在水平和垂直扫描中,平行性与视敏度,水平变形评分和垂直变形评分显着相关。在水平扫描中,中心点的平行度(1mm)与水平变形评分(R = -0.632; P <.0001)密切相关。在水平和垂直扫描中都发现平行度和视网膜厚度之间存在显着的负相关。结论ERM眼的平行度明显低于正常眼,并且与ERM眼的变态和视敏度密切相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号