首页> 外文期刊>Journal of Nondestructive Evaluation >The Use of Acoustic Emission Intensity Analysis for the Assessment of Cover Crack Growth in Corroded Concrete Structures
【24h】

The Use of Acoustic Emission Intensity Analysis for the Assessment of Cover Crack Growth in Corroded Concrete Structures

机译:声发射强度分析对腐蚀混凝土结构覆盖裂纹增长评估

获取原文
获取原文并翻译 | 示例
           

摘要

In this paper, acoustic emission (AE) intensity analysis was utilized to assess the concrete cover cracking due to steel corrosion in reinforced concrete structures. A total of 30 reinforced concrete prism samples were tested under an accelerated corrosion test coupled with continuous AE monitoring using attached AE sensors. The samples were cast with three concrete cover thicknesses (20, 30 and 40 mm) around steel bars and were exposed to five percentages of steel mass loss: 1, 2, 3, 4, and 5%. The cover cracking was monitored daily by visual inspection to detect and measure crack widths. Different AE signal parameters were continuously recorded during the tests, including number of hits, signal strength, energy, and amplitude. The acquired AE events were subjected to an intensity analysis of signal strength to estimate historic index (H(t)) and severity (S_r). In addition, a b value analysis was conducted on all AE data and the results were compared to those obtained from the intensity analysis. The results showed that increasing the cover thickness had no significant impact on AE parameters (number of hits, cumulative signal strength, cumulative energy, amplitude, H(t), and S_r) at similar values of crack growth. Nonetheless, varying the cover thickness from 20 to 40 mm resulted in lower crack widths and slightly higher b values at the same levels of steel mass loss. It was also found that both H(t) and S_r showed a more evident correlation with the values of crack growth than did b values, regardless of cover thickness or percentage of steel mass loss. Finally, an intensity classification chart was developed to quantify
机译:本文利用声发射(AE)强度分析来评估钢筋混凝土结构中钢腐蚀引起的混凝土盖裂纹。在加速腐蚀试验下,使用连接的AE传感器的连续AE监测,在加速腐蚀试验中进行总共进行30个钢筋混凝土棱镜样品。将样品缠绕在钢筋周围的三个混凝土盖厚度(20,30和40mm),并暴露于钢质量损失的五个百分比:1,2,3,4和5%。通过目视检查每天监测盖子裂纹,以检测和测量裂缝宽度。在测试期间连续记录不同的AE信号参数,包括命中数,信号强度,能量和幅度。获得的AE事件对信号强度分析进行了强度分析,以估计历史指数(H(T))和严重程度(S_R)。另外,在所有AE数据上进行B值分析,并将结果与​​从强度分析中获得的那些进行比较。结果表明,在裂纹生长的类似值下,增加覆盖厚度对AE参数(次数,累积信号强度,累积能量,幅度,H(T)和S_R)没有显着影响。尽管如此,改变20至40mm的覆盖厚度导致较低的裂缝宽度和略高的B值在相同水平的钢质量损失。还发现H(t)和S_R两者和S_R与裂纹生长值更明显相关,而不是B值,而不管覆盖厚度或钢质量损失的百分比。最后,开发了强度分类图表来量化

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号