...
首页> 外文期刊>Journal of clinical neuroscience: official journal of the Neurosurgical Society of Australasia >DynaCT imaging for intraprocedural evaluation of flow-diverting stent apposition during endovascular treatment of intracranial aneurysms
【24h】

DynaCT imaging for intraprocedural evaluation of flow-diverting stent apposition during endovascular treatment of intracranial aneurysms

机译:颅内动脉瘤腹血管治疗血管内血管治疗流动转移支架与颅内血管分析的Dynact成像

获取原文
获取原文并翻译 | 示例
           

摘要

The treatment of large, complex intracranial aneurysms is being increasingly performed using flow-diverting stents (FDS) such as the Pipeline Embolization Device (PED; ev3, Irvine, CA, USA). Malapposition of a FDS to the parent artery wall decreases the likelihood of aneurysm obliteration and increases the risk of both immediate and delayed complications. DynaCT scanning (Siemens Medical Solutions, Erlangen, Germany) is a novel imaging modality which uses a flat plane detector to generate CT images using the same C-arm employed for digital subtraction angiography. We present a 40-year-old woman with an unruptured, 11 mm cavernous internal carotid artery aneurysm who was treated with endovascular obliteration using a PED. Intraprocedural DynaCT scan performed after PED deployment demonstrated incomplete stent apposition to the parent vessel which could not be detected on digital subtraction angiography alone. Balloon angioplasty was performed to improve apposition of the stent to the vessel wall. There were no procedural or clinical complications. The aneurysm shrank in size at follow-up angiography 6 months after the procedure and will be monitored for progressive occlusion. While gross stent malapposition is readily evident after stent deployment, minor instances of malapposition may be undetectable by standard angiography. Therefore the use of DynaCT imaging may improve intraprocedural stent visualization and potentially avert long-term endovascular aneurysm treatment complications associated with inadequate stent apposition.
机译:使用诸如管道栓塞装置(PED; EV3,IRVINE,CA,USA)的流量转移支架(FDS)越来越多地进行大型复杂颅内动脉瘤的处理。 FDS对母动壁的FDS对母动脉堵塞的可能性降低了动脉瘤爆发的可能性,并增加了即时和延迟并发症的风险。 Dynact扫描(西门子医疗解决方案,Erlangen,德国)是一种新的成像模型,它使用平面检测器使用用于数字减法血管造影的相同的C形臂产生CT图像。我们展示了一名40岁的女性,一个未破产,11毫米海绵状颈动脉动脉瘤,使用PED治疗血管内爆破。在PED部署后执行的颅内透过扫描对单独的数字减法血管造影无法检测到不完全的支架。进行气球血管成形术,以改善支架与血管壁的环容。没有程序或临床并发症。动脉瘤在手术后的后续血管造影大小缩小,并将监测进行渐进式闭塞。虽然在支架部署后易于显而易见的,但是,标准血管造影可能无法检测到较小的恶作剧的轻微实例。因此,使用Dynact成像可以改善颅内支架可视化,并且可能避免长期血管内动脉瘤治疗并发症,与支架相应不足。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号