The time delay caused by the digital computation and the update of the duty cycle tend to worsen the dynamic performance of digitally controlled power converters. This paper proposes a real-time calculation method for single-phase cascaded H-bridge (CHB) inverters with the phase-shifted carrier pulsewidth modulation (PSC-PWM) to eliminate the time delay caused by the digital computation in the control loop without the loss of duty cycle. In the approach, a sampling method for the PSC-PWM applied in a single-phase CHB inverter is introduced, which samples the current and voltage at points of the intersection for triangular carriers of legs in all adjacent H-bridge cells. The sampling method is used alternately with the conventional regular sampling method by following a selection rule in order to avoid the loss of duty cycle. Experimental results verify that the proposed method effectively improves the transient performance of the current control loop and suppresses the effect of the distortion of the grid voltage on the line current.
机译:由数字计算和占空比更新引起的时间延迟倾向于恶化数字控制功率转换器的动态性能。本文提出了一种具有相位移位载波脉冲宽度调制(PSC-PWM)的单相级联H桥(CHB)逆变器的实时计算方法,以消除控制循环中的数字计算引起的时间延迟而没有失去占空比。在该方法中,引入了用于在单相CHB逆变器中施加的PSC-PWM的采样方法,其在所有相邻的H桥单元中对三角形载体的交叉点的点进行采样。采样方法通过遵循选择规则来交替使用传统的规则采样方法,以避免占空比丢失。实验结果验证了该方法有效提高了电流控制回路的瞬态性能,并抑制了电网电压失真对线电流的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号