摘要

The aim of this study was to investigate conventionally and early loaded titanium and titanium–zirconium alloy implants by three-dimensional finite element stress analysis. Three-dimensional model of a dental implant was created and a thread area was established as a region of interest in trabecular bone to study a localized part of the global model with a refined mesh. The peri-implant tissues around conventionally loaded (model 1) and early loaded (model 2) implants were implemented and were used to explore principal stresses, displacement values, and equivalent strains in the peri-implant region of titanium and titanium–zirconium implants under static load of 300 N with or without 30° inclination applied on top of the abutment surface.
机译:本研究的目的是通过三维有限元应力分析来研究常规和早期的载钛和钛 - 锆合金植入物。 创建了牙科植入物的三维模型,并建立了螺纹区域作为小梁骨的感兴趣区域,以研究全球模型的局部部分与精致网格。 常规装载(模型1)和早期装载(型号2)植入物周围的围植入组织并用于探索钛和锆植入物的PERI-植入区域中的主要应力,位移值和等效菌株 300 n的静压负载,有或没有30°倾斜在邻接表面的顶部上施加。