首页> 外文期刊>International journal of applied mechanics >Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations
【24h】

Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations

机译:用二维复制品测量全覆盖修复率的二维复制品方法的三维数字技术比较

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE. This study compared digital (reference point matching) and replica methods for measuring marginal and internal fit of full coverage restorations. MATERIALS AND METHODS. A maxillary left first molar typodent was fixed on to an aluminum base and prepared to receive all-ceramic full coverage restoration. The model was scanned with an intraoral scanner (CEREC Omnicam, Sirona, York, PA, USA). Twelve crowns were fabricated from lithium disilicate blocks (IPS emax CAD, Ivoclar Vivadent) and then crystalized. Marginal and internal fit of each restoration was measured by two examiners using replica and a new digital three-dimensional technique. Reliability between the two methods and two examiners was assessed by correlation and Cronbach's Alpha coefficient (P<.05). A Bland-Altman assessment for agreement was used to compare the two methods. RESULTS. Bland-Altman assessment showed that the mean of difference for marginal, absolute marginal, and axial gap was respectively -1.04 mu m, -41.9 mu m, and -29.53 mu m with limit of agreement (LOA) between -37.26 to 35.18 mu m for marginal, -105.85 to 22.05 mu m for absolute marginal and -80.52 to 22.02 mu m for axial gap. Positive correlation for repeatability (P<.05) in determining marginal and internal gaps by the two examiners in both techniques was revealed. Reliability of both techniques in all sites of measurements was at least good (0.8 <= alpha <= 0.9). CONCLUSION. Both measuring techniques appeared highly reliable for evaluating fit of fixed dental restorations, while reference point matching provided higher values in axial and absolute marginal gap assessment.
机译:目的。本研究比较了数字(参考点匹配)和复制方法,用于测量完整覆盖修复的边缘和内部拟合。材料和方法。将上颌左第一磨牙典型分子固定在铝基底座上,并准备接收全陶瓷的全覆盖恢复。该模型用境内扫描仪(Cerecomnicam,Sirona,York,Pa,USA)扫描了模型。从锂静止嵌段(IPS Emax CAD,IVOClar Vievadent)制造十二冠,然后是结晶的。每次恢复的边缘和内部拟合由两位审查员使用复制品和新的数字三维技术来测量。通过相关性和Cronbach的alpha系数评估两种方法和两项检查员之间的可靠性(P <.05)。用于协议的Bland-Altman评估用于比较这两种方法。结果。 Bland-Altman评估表明,边际,绝对边缘和轴向间隙的差异分别为-1.04 mu m,-41.9 mu m,和-29.53 mu m,协议限制 - 37.26至35.18 mu m之间对于极端边缘,绝对边缘和22.05亩,对于轴向间隙,绝对边缘至-80.52至22.02亩。揭示了两种审查员在两种方法中确定边缘和内部间隙的重复性(P <.05)的正相关。所有测量部位的两种技术的可靠性至少良好(0.8 <=α<= 0.9)。结论。两种测量技术都非常可靠地评估固定牙科修复体的适合,而参考点匹配在轴向和绝对边缘间隙评估中提供更高的值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号