首页> 外文期刊>Cytometry, Part B. Clinical cytometry: the journal of the International Society for Analytical Cytology >CD4(+) T lymphocytes enumeration by an easy-to-use single platform image cytometer for HIV monitoring in resource-constrained settings
【24h】

CD4(+) T lymphocytes enumeration by an easy-to-use single platform image cytometer for HIV monitoring in resource-constrained settings

机译:通过简单易用的单平台图像细胞仪对CD4(+)T淋巴细胞进行计数,可用于资源受限环境中的HIV监测

获取原文
获取原文并翻译 | 示例
           

摘要

Background: HIV monitoring in resource-constrained settings demands affordable and reliable CD4(+) T lymphocytes enumeration methods. We developed a simple single platform image cytometer (SP ICM), which is a dedicated volumetric CD4(+) T lymphocytes enumeration system that uses immunomagnetic and immunofluorescent technologies. The instrument was designed to be a low-cost, yet reliable and robust one. In this article we test the instrument and the immunochemical procedures used on blood from HIV negative and HIV positive patients. Methods: After CD4 immunomagnetic labeling in whole blood, CD4(+) T lymphocytes, CD4(+dim) monocytes and some nonspecifically labeled cells are magnetically attracted to an analysis surface. Combining with CD3-Phycoerythrin (PE) labeling, only CD3(+)CD4(+) T lymphocytes are fluorescently labeled and visible in a fluorescent image of the analysis surface. The number of CD4(+) T lymphocytes is obtained by image analysis. Alternatively, CD3 immunomagnetic selection in combination with CD4 immunofluorescent labeling can also be applied for CD4(+) T lymphocytes enumeration. Results: The SP ICM system was compared with two single platform flow cytometer (SP FCM) methods: tetraCXP and TruCount methods. The SP ICM system has excellent precision, accuracy and linearity for CD4(+) T lymphocytes enumeration. Good correlations were obtained between the SP ICM and the SP FCM methods for blood specimens of 44 HIV- patients, and of 63 HIV+ patients. Bland-Altman plots showed interchangeability between the SP ICM and the SP FCM methods. Conclusions: The immunolabeling methods and the instrumentation are simple and easy-to-handle for less-trained operators. The SP ICM system is a good candidate for CD4(+) T lymphocytes enumeration in point-of-care settings of resource-constrained countries. (c) 2007 Clinical Cytometry Society.
机译:背景:在资源有限的环境中进行HIV监测需要可负担且可靠的CD4(+)T淋巴细胞计数方法。我们开发了一个简单的单平台图像细胞仪(SP ICM),它是使用免疫磁性和免疫荧光技术的专用体积CD4(+)T淋巴细胞计数系统。该仪器设计为低成本,可靠且坚固的仪器。在本文中,我们测试了用于HIV阴性和HIV阳性患者血液的仪器和免疫化学程序。方法:在全血中进行CD4免疫磁标记后,将CD4(+)T淋巴细胞,CD4(+ dim)单核细胞和一些非特异性标记的细胞磁吸引到分析表面。结合CD3-藻红蛋白(PE)标记,只有CD3(+)CD4(+)T淋巴细胞被荧光标记,并且在分析表面的荧光图像中可见。通过图像分析获得CD4(+)T淋巴细胞的数量。或者,也可以将CD3免疫磁性选择与CD4免疫荧光标记相结合,用于CD4(+)T淋巴细胞计数。结果:将SP ICM系统与两种单平台流式细胞仪(SP FCM)方法进行了比较:tetraCXP和TruCount方法。 SP ICM系统具有出色的精度,准确性和线性,可用于CD4(+)T淋巴细胞计数。 SP ICM和SP FCM方法对44例HIV患者和63例HIV +患者的血液样本具有良好的相关性。 Bland-Altman图显示了SP ICM和SP FCM方法之间的互换性。结论:免疫标记方法和仪器操作简单,易于培训,操作人员较少。 SP ICM系统是资源有限国家的即时医疗机构CD4(+)T淋巴细胞计数的理想选择。 (c)2007临床细胞计数学会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号