首页> 外文期刊>British journal of ophthalmology >Multicentre clinical study of the herpes simplex virus immunochromatographic assay kit for the diagnosis of herpetic epithelial keratitis
【24h】

Multicentre clinical study of the herpes simplex virus immunochromatographic assay kit for the diagnosis of herpetic epithelial keratitis

机译:疱疹病毒免疫层状测定试剂盒用于诊断肝脏上皮角膜炎的多期临床研究

获取原文
获取原文并翻译 | 示例
           

摘要

Background/aims: The novel immunochromatographic assay (ICGA) kit was recently developed to diagnose herpes simplex virus (HSV) infection. This multicentre study aimed to evaluate the value of the ICGA kit for the diagnosis of herpetic epithelial keratitis by comparing it with immunofluorescence assay (IFA) and real-time PCR. Methods: Corneal scrapings were collected from 117 patients, including 77 with herpetic keratitis as their final clinical diagnosis as well as 40 others at 21 facilities. These samples were tested by the ICGA kit, IFA and real-time PCR. Results: The positive concordance between final clinical diagnosis and ICGA was 46.7% (35/75 cases) and the negative concordance was 100% (39/39). The positive and negative concordance between real-time PCR and ICGA were 57.4% (35/61 cases) and 100% (53/53), respectively. The positive and negative concordance between IFA and ICGA were 61.1% (22/36 cases) and 83.3% (55/66), respectively. In 92 cases where anti-HSV drugs were not prescribed prior to corneal scraping, the positive and negative concordance between final clinical diagnosis and ICGA were 55.0% (33/60 cases) and 100% (32/32), respectively. Conclusions: The ICGA kit has moderate sensitivity and high specificity, indicating clinical utility in the diagnosis of herpetic epithelial keratitis.
机译:背景/目的:最近开发了新型免疫色谱法测定(ICGA)试剂盒以诊断单纯疱疹病毒(HSV)感染。这种多期面研究旨在通过将其与免疫荧光测定(IFA)和实时PCR进行比较来评估ICGA套件的诊断价值。方法:从117名患者中收集角膜刮痧,其中包括77例,具有引用角膜炎,作为其最终临床诊断,以及21种设施的其他40名。通过ICGA试剂盒,IFA和实时PCR测试这些样品。结果:最终临床诊断和ICGA之间的积极一致性为46.7%(35/75例),负面的一致性100%(39/39)。实时PCR和ICGA之间的正负一致性分别为57.4%(35/61例)和100%(53/53)。 IFA和ICGA之间的正负一致性分别为61.1%(22/36例)和83.3%(55/66)。在抗角膜擦伤之前未在抗HSV药物未处方的92例中,最终临床诊断和ICGA之间的正负一致性分别为55.0%(33/60例)和100%(32/32)。结论:ICGA试剂盒具有中度敏感性和高特异性,表明临床效用在诊断引物上皮角膜炎的诊断。

著录项

  • 来源
    《British journal of ophthalmology》 |2013年第9期|共5页
  • 作者单位

    Division of Ophthalmology and Visual Science Faculty of Medicine Tottori University 36-1 Nishi;

    Department of Ophthalmology Faculty of Medicine Kinki University Osaka-Sayama Osaka Japan;

    Department of Ophthalmology Faculty of Medicine Kinki University Osaka-Sayama Osaka Japan;

    Division of Ophthalmology and Visual Science Faculty of Medicine Tottori University 36-1 Nishi;

    Department of Ophthalmology and Regenerative Medicine Ehime University Graduate School of Medicine;

    Department of Ophthalmology Kanazawa Medical University Uchinada Ishikawa Japan;

    Department of Ophthalmology Hokkaido University Graduate School of Medicine Sapporo Hokkaido;

    Department of Ophthalmology Institute of Health Biosciences University of Tokushima Graduate;

    Division of Ophthalmology Department of Visual Sciences Nihon University School of Medicine;

    Okamoto Eye Clinic Matsuyama Ehime Japan;

    Ideta Eye Hospital Kumamoto Japan;

    Ueno Eye Clinic Tokyo Japan;

    Hatano Eye Clinic Fujisawa Kanagawa Japan;

    Tokushima Eye Clinic Tokyo Japan;

    Yoshinocho Eye Clinic Yokohama Kanagawa Japan;

    Hirahara Eye Clinic Odawara Kanagawa Japan;

    Nagatsuta Eye Clinic Yokohama Kanagawa Japan;

    Totsuka Hiro Eye Clinic Yokohama Kanagawa Japan;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 眼科学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号