首页> 外文期刊>Biosystems Engineering >Evaluation of a dry filter and an electrostatic precipitator for exhaust air cleaning at commercial non-cage laying hen houses
【24h】

Evaluation of a dry filter and an electrostatic precipitator for exhaust air cleaning at commercial non-cage laying hen houses

机译:在商用无笼产蛋鸡舍中评估用于干燥空气净化的干式过滤器和静电除尘器

获取原文
获取原文并翻译 | 示例
           

摘要

The removal performance of two exhaust air cleaning systems for abatement of particulate matter (PM) emission in poultry houses were investigated: a commercially available dry filter (DF) and a full-scale prototype electrostatic precipitator (ESP). Each system was connected to two commercial, non-cage laying hen houses: one with aviary housing, the other with floor housing. At each house, six to nine 24-h measurements were carried out, spread over the year and the laying cycle. Upstream and downstream of the systems, we measured PM10, PM2.5, and carbon dioxide concentrations, temperature, and relative humidity. Additional measurements of particle size distribution only were carried out at the DF of another poultry house. The latter showed that removal of PM by the DF increased with increasing particle diameter. Mean removal efficiency of the DF for PM10 was 40.1%, whereas PM2.5 was not significantly removed. The ESP reduced concentrations of PM10 by an average of 57.0% and concentrations of PM2.5 by an average of 45.3%. For neither of the two systems an effect of upstream PM concentration on removal performance was found. Results of this study are compared with the available literature and possibilities to improve removal performance are discussed. The mean (SD between houses) untreated emissions rate from the non-cage layer houses was 7.81 (4.12) mg PM20 h(-1) bird(-1) and 0.44 (0.28) mg PM2.5 h(-1) bird(-1). In conclusion, the evaluated systems show potential to reduce PM emissions from poultry houses. (C) 2014 IAgrE. Published by Elsevier Ltd. All rights reserved.
机译:研究了用于减少禽舍中颗粒物(PM)排放的两种排气净化系统的去除性能:商用干式过滤器(DF)和大型静电除尘器(ESP)。每个系统都连接到两个商业,无笼子的蛋鸡舍:一个带鸟舍,另一个带地板舍。在每个房屋中,进行了六到九次24小时测量,分布在全年和铺设周期中。在系统的上游和下游,我们测量了PM10,PM2.5以及二氧化碳浓度,温度和相对湿度。仅在另一家禽舍的DF处进行了粒度分布的附加测量。后者表明,DF去除PM随粒径增加而增加。 DF对PM10的平均去除效率为40.1%,而PM2.5并未被明显去除。 ESP将PM10的浓度平均降低了57.0%,将PM2.5的浓度平均降低了45.3%。对于这两个系统,均未发现上游PM浓度对去除性能的影响。将该研究结果与现有文献进行比较,并讨论了改善去除性能的可能性。非笼状层房屋的未处理平均排放率(SD)为7.81(4.12)mg PM20 h(-1)禽(-1)和0.44(0.28)mg PM2.5 h(-1)禽( -1)。总之,所评估的系统显示出减少禽舍PM排放的潜力。 (C)2014年。由Elsevier Ltd.出版。保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号