首页> 外文期刊>Water Science and Technology >Particle counter as a tool to control pre-hydrolyzed coagulant dosing and rapid filtration efficiency in a conventional treatment system
【24h】

Particle counter as a tool to control pre-hydrolyzed coagulant dosing and rapid filtration efficiency in a conventional treatment system

机译:在常规处理系统中,颗粒计数器可作为控制预水解凝结剂定量和快速过滤效率的工具

获取原文
获取原文并翻译 | 示例
           

摘要

Filtration efficiency in a conventional water treatment system was analyzed in the context of pre-hydrolyzed coagulant overdosing. Two commercial coagulants of different aluminum speciation were tested. A study was carried out at a water treatment plant supplied with raw water of variable quality. The lack of stability of water quality caused many problems with maintaining the optimal coagulant dose. The achieved results show that the type of coagulant had a very strong influence on the effectiveness of filtration resulting from the application of an improper coagulant dose. The overdosing of high basicity coagulant (PAC85) caused a significant increase of fine particles in the outflow from the sedimentation tanks, which could not be retained in the filter bed due to high surface charge and the small size of hydrolysis products. When using a coagulant of lower basicity (PAC70), it was much easier to control the dose of coagulant and to adjust it to the changing water quality.
机译:在预水解凝结剂过量的情况下,分析了常规水处理系统中的过滤效率。测试了两种不同铝形态的商业混凝剂。在提供了不同质量原水的水处理厂进行了研究。水质缺乏稳定性导致在维持最佳混凝剂剂量方面存在许多问题。所获得的结果表明,凝结剂的类型对由于施加不正确的凝结剂剂量而对过滤效果产生非常强烈的影响。高碱性凝结剂(PAC85)的过量使用导致从沉淀池流出的细颗粒显着增加,由于高表面电荷和较小的水解产物,这些细颗粒无法保留在滤床上。当使用碱度较低的凝结剂(PAC70)时,控制凝结剂的剂量并根据不断变化的水质进行调节要容易得多。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号