首页> 外文期刊>Analytical chemistry >Dual-View Imaging System Using a Wide-Range Dichroic Mirror for Simultaneous Four-Color Single-Molecule Detection
【24h】

Dual-View Imaging System Using a Wide-Range Dichroic Mirror for Simultaneous Four-Color Single-Molecule Detection

机译:使用大范围二向色镜的双视图成像系统,用于同时四色单分子检测

获取原文
获取原文并翻译 | 示例
           

摘要

A dual-view imaging system for simultaneous four-color single-molecule (SM) detection was developed. As for the detection procedure, four species of SM fluorophores, namely, Alexa 488, 555, 647, and 680, are immobilized on different slides and excited by evanescent-wave illumination. Fluorescence emitted from an SM fluorophore is split by a wide-range dichroic mirror (WR DM) in a dual-view optics and imaged as two SM fluorescence spots (SM spots) on an electron-multiplying charge-coupled device (EM-CCD) at 100 Hz. The transmittance of the WR DM changes gradually over the wavelength range of 500 to 700 nm so that the signal ratios of the two SM spots for the four fluorophore species differ. A method for classifying SM fluorophores into four species in accordance with their signal ratios was developed. It was used to classify 597 SM fluorophores at an accuracy of above 98percent for all the species. This accuracy is comparable to that of a conventional four-color SM detection system. To classify four species, the conventional system disperses SM fluorescence with a prism and provides an elongated SM spot that uses more pixels of an EM-CCD chip than that of the developed system. The developed system can thus detect 1.5-fold more SM spots with the same-size EM-CCD chip, so it can achieve 1.5-fold higher throughput. Moreover, the developed system is based on a simple and practical approach, namely, replacing an ordinary dichroic mirror in a commercially available dual-view optics with a WR DM. This replacement transforms a dual-view imaging system for two-color detection into a system for four-color detection. The developed system is suitable for detection systems of next-generation DNA sequencers and DNA microarray-chip analyzers.
机译:开发了用于同时检测四色单分子(SM)的双视图成像系统。至于检测程序,将四种SM荧光团,即Alexa 488、555、647和680固定在不同的载玻片上,并通过e逝波照明激发。 SM荧光团发出的荧光被双视光学系统中的大范围二向色镜(WR DM)分开,并在倍增电子耦合的电荷耦合器件(EM-CCD)上成像为两个SM荧光点(SM点)。在100 Hz WR DM的透射率在500到700 nm的波长范围内逐渐变化,因此四种荧光团的两个SM点的信号比不同。提出了根据信号比将SM荧光团分为四种的方法。它用于对597种SM荧光团进行分类,所有物种的准确度均在98%以上。该精度可与传统的四色SM检测系统相媲美。为了对四个种类进行分类,常规系统用棱镜分散SM荧光,并提供一个细长的SM点,该点使用EM-CCD芯片的像素要多于开发的系统。因此,开发的系统可以使用相同尺寸的EM-CCD芯片检测到1.5倍的SM点,因此可以实现1.5倍的高吞吐量。此外,所开发的系统基于一种简单实用的方法,即用WR DM代替市售双视光学系统中的普通二向色镜。该替换将用于双色检测的双视图成像系统转换为用于四色检测的系统。该开发的系统适用于下一代DNA测序仪和DNA微阵列芯片分析仪的检测系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号