Novel on-line column extraction apparatus coupled with binary peak focusing for high-performance liquid chromatography determination of rifampicin in human plasma: A strategy for therapeutic drug monitoring

机译:新型在线柱萃取装置与二元峰聚焦相结合用于高效液相色谱法测定人血浆中的利福平:治疗药物监测的策略

获取原文
获取原文并翻译 | 示例
           

摘要

In order to develop a method that is completely suitable for the routine therapeutic drug monitoring, a sensitive and fully automated on-line column extraction apparatus in combination with high-performance liquid chromatography allowing binary peak focusing was developed and validated for the determination of rifampicin in human plasma. Rifapentine was used as an internal standard. The analytical cycle started with the injection of 100 mu L of the sample pretreated by protein precipitation in a Venusil SCX extraction column. After the elution, the analytes were transferred and concentrated in an Xtimate C-18 trap column. Finally, the trapped analytes were separated by an Xtimate C-18 analytical column and were analyzed by an ultraviolet detector at 336 nm. With this new strategy, continuous on-line analysis of the compounds was successfully performed. The method showed excellent performance for the analysis of rifampicin in plasma samples, including calibration curve linearity (All r were larger than 0.9996), sensitivity (lowest limit of quantification was 0.12 mu g/mL), method accuracy (within 6.6% in terms of relative error), and precision (relative standard deviations of intra- and interday precision were less than 7.8%). These results demonstrated that the simple, reliable, and automatic method based on on-line column extraction and binary peak focusing is a promising approach for therapeutic drug monitoring in complex biomatrix samples.
机译:为了开发一种完全适合常规治疗药物监测的方法,开发了一种灵敏且全自动的在线柱提取设备与高效液相色谱仪结合使用,可实现二元峰聚焦,并验证了该方法可用于测定利福平。人血浆。利福喷丁用作内标。分析周期开始于在Venusil SCX萃取柱中注入100 µL经过蛋白质沉淀预处理的样品。洗脱后,将分析物转移并在Xtimate C-18捕集柱中浓缩。最后,通过Xtimate C-18分析柱分离捕获的分析物,并通过紫外检测器在336 nm处进行分析。通过这种新策略,成功地进行了化合物的连续在线分析。该方法在分析血浆样品中的利福平方面表现出优异的性能,包括校准曲线线性(所有r均大于0.9996),灵敏度(最低定量限为0.12μg / mL),方法准确度(在6.6%以内)。相对误差)和精度(日内和日间精度的相对标准偏差小于7.8%)。这些结果表明,基于在线柱提取和二元峰聚焦的简单,可靠和自动的方法是用于复杂生物基质样品中治疗药物监测的有前途的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号