...
首页> 外文期刊>Journal of glaucoma >The Relation of White-on-White Standard Automated Perimetry, Short Wavelength Perimetry, and Optic Coherence Tomography Parameters in Ocular Hypertension
【24h】

The Relation of White-on-White Standard Automated Perimetry, Short Wavelength Perimetry, and Optic Coherence Tomography Parameters in Ocular Hypertension

机译:高血压患者白标准自动视野检查法,短波长视野检查法和光学相干断层扫描参数之间的关系

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose:The purpose of this study is to examine the demographics, clinical properties, and the relation between white-on-white standard automated perimetry (SAP), short wavelength automated perimetry (SWAP), and optical coherence tomographic (OCT) parameters of patients with ocular hypertension.Materials and Methods:Sixty-one eyes of 61 patients diagnosed with ocular hypertension in the Ankara Numune Education and Research Hospital ophthalmology unit between January 2010 and January 2011 were included in this study. All patients underwent SAP and SWAP tests with the Humphrey visual field analyser using the 30.2 full-threshold test. Retinal nerve fiber layers (RNFL) and optic nerve heads of patients were evaluated with Stratus OCT.Results:Positive correlation was detected between SAP pattern standard deviation value and average intraocular pressure (P=0.017), maximum intraocular pressure (P=0.009), and vertical cup to disc (C/D) ratio (P=0.009). Positive correlation between SWAP median deviation value with inferior (P=0.032), nasal (P=0.005), 6 o'clock quadrant RNFL thickness (P=0.028), and I-max/T-avg ratio (P=0.023) and negative correlation with S-max/N-avg ratio (P=0.005) were detected. There was no correlation between central corneal thickness and peripapillary RNFL thicknesses (P>0.05).Conclusions:There was no relation between SAP median deviation, pattern standard deviation values and RNFL thicknesses and optic disc parameters of the OCT. By contrast significant correlation between several SWAP parameters and OCT parameters were detected. SWAP appeared to outperform achromatic SAP when the same 30-2 method was used.
机译:目的:本研究的目的是检查患者的人口统计学,临床特征以及其白标准自动视野检查(SAP),短波长自动视野检查(SWAP)和患者的光学相干断层扫描(OCT)参数之间的关系材料与方法:研究对象:2010年1月至2011年1月在安卡拉Numune教育研究医院眼科诊断为高眼压的61例患者的六十一只眼。所有患者均使用30.2全阈值测试,使用汉弗莱视野分析仪进行SAP和SWAP测试。用Stratus OCT评估患者的视网膜神经纤维层(RNFL)和视神经乳头。结果:检测到SAP模式标准差值与平均眼压(P = 0.017),最大眼压(P = 0.009)之间呈正相关,垂直杯对盘(C / D)的比例(P = 0.009)。 SWAP中位偏差值与下(P = 0.032),鼻(P = 0.005),6点象限RNFL厚度(P = 0.028)和I-max / T-avg比(P = 0.023)之间呈正相关检测到与S-max / N-avg比率呈负相关(P = 0.005)。结论:OCT的SAP中位偏差,图案标准偏差值,RNFL厚度与视盘参数之间无相关性(P> 0.05)。相比之下,检测到几个SWAP参数和OCT参数之间的显着相关性。当使用相同的30-2方法时,SWAP似乎胜过无彩色SAP。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号