Background: Oxidized lipoprotein(a) [ox-Lp(a)] and oxidizedlow density lipoprotein (ox-LDL) levels have been reported to be useful predictors of cardiovascular events.The study developed a chemiluminescence (CL) imaging immunoassay method for simultaneously detecting serumconcentrations of ox-Lp(a) and ox-LDL. Methods: Ox-Lp(a) and ox-LDL levels were measured by CL imaging immunoassay using a disposable immunosensor array as the carrier and a charge-coupled device as the detector, and were studied in 46 acute coronary syndromes (ACS) patients, 58 stable coronary artery disease (CAD) and 61 control subjects.Results: This method showed good linear relations (R2 0.99) in the concentration range of 2.00 × 10-5- 2.00 × 10-1 and 2.40 × 10-4-2.40 U/mL for ox-Lp(a) and ox-LDL, respectively. The detection limits for ox-Lp(a) and ox-LDL were 2.40 × 10-6 and 3.00 × 10-5 U/mL, respectively. The intra- and inter-assay coefficients of variation (CV) were 4.90%-6.76% and 7.11%-10.06% for ox-Lp(a), and5.01%-6.04% and 5.47%-9.77% for ox-LDL, respectively. The mean recovery was 99.31% for ox-Lp(a) and 99.57% for ox-LDL, respectively. Significant correlations were observed between ox-Lp(a) levels detected by CL imaging immunoassay and ELISA, and between ox-LDL levels detected by the two methods, respectively. Furthermore, ox-Lp(a) and ox-LDL levels increased in stable CAD, and especially in ACS. Conclusions: The CL imaging immunoassay provided a simple, sensitive and reliable method for the simultaneous determination of serum ox-Lp(a) and ox-LDL. The clinical monitoring ox-Lp(a) and ox-LDL levels may possess distinctly clinical value for assessment of CAD risk.
机译:背景:据报道,氧化脂蛋白(a)[ox-Lp(a)]和氧化低密度脂蛋白(ox-LDL)水平可预测心血管事件。该研究开发了一种化学发光(CL)成像免疫测定方法,用于同时检测血清ox-Lp(a)和ox-LDL的浓度。方法:采用一次性免疫传感器阵列作为载体,采用电荷耦合装置作为检测器,通过CL成像免疫分析法测定ox-Lp(a)和ox-LDL水平,并在46例急性冠脉综合征(ACS)患者中进行了研究,结果:该方法在2.00×10-5- 2.00×10-1和2.40×10-4-2.40的浓度范围内表现出良好的线性关系(R2> 0.99),具有58个稳定的冠状动脉疾病(CAD)和61个对照组。 ox-Lp(a)和ox-LDL的U / mL。 ox-Lp(a)和ox-LDL的检出限分别为2.40×10-6和3.00×10-5 U / mL。 ox-Lp(a)的批内和批间变异系数(CV)为4.90%-6.76%和7.11%-10.06%,ox-LDL为5.01%-6.04%和5.47%-9.77% , 分别。 ox-Lp(a)的平均回收率分别为99.31%和ox-LDL的99.57%。通过CL成像免疫测定法和ELISA检测到的ox-Lp(a)水平之间以及通过两种方法检测到的ox-LDL水平之间均存在显着相关性。此外,在稳定的CAD中,尤其是在ACS中,ox-Lp(a)和ox-LDL水平升高。结论:CL成像免疫测定法为同时测定血清ox-Lp(a)和ox-LDL提供了一种简单,灵敏和可靠的方法。临床监测ox-Lp(a)和ox-LDL水平可能具有明显的临床价值,可用于评估CAD风险。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号